Effect of humidity on the breakdown characteristics of air in non-uniform fields at 30 kHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
10
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 14 publications
3
10
0
Order By: Relevance
“…For the configurations exhibiting corona, a nearly linear decrease in the breakdown voltage with humidity was observed. No influence of humidity was observed for gaps having streamers before breakdown 5.…”
Section: Breakdown Voltage Datamentioning
confidence: 90%
See 1 more Smart Citation
“…For the configurations exhibiting corona, a nearly linear decrease in the breakdown voltage with humidity was observed. No influence of humidity was observed for gaps having streamers before breakdown 5.…”
Section: Breakdown Voltage Datamentioning
confidence: 90%
“…Breakdown voltage versus gap length for the uniform field gap configuration for a humidity level of 10% RH. Curves are based on experimental data 4, 5.…”
Section: Breakdown Voltage Datamentioning
confidence: 99%
“…26 And the bonding of water molecules with surface charges destroyed the low adhesion of the superhydrophobic samples. 27,28 Therefore, the droplet did not leave the surface (Fig. 10(c)) and arc discharge happened on the sample for the second and third times of applying voltage (Figs.…”
Section: Aip Advances 8 035117 (2018)mentioning
confidence: 99%
“…On the other hand, compressed air contains more moisture than the other candidate gases. Rodriguez et al [31,32] and H. F. A Verhaart et al [33] studied this humidity effect on the insulation characteristics in air under uniform and non-uniform fields respectively. The breakdown voltage was positively correlated with humidity under a uniform field [31].…”
Section: Surface Flashover Voltage Characteristicsmentioning
confidence: 99%
“…This breakdown voltage improvement was attributed to the increase in the electron absorption rate and the attachment coefficient (η) caused by water molecules [31,33,34]. On the other hand, there was a negative correlation between the flashover voltage and humidity under a non-uniform field in which corona occurred prior to the termination of breakdown [32]. In other words, the breakdown voltage decreases with humidity because of the influence of corona under a nonuniform field.…”
Section: Surface Flashover Voltage Characteristicsmentioning