2021
DOI: 10.1016/j.hrtlng.2020.06.013
|View full text |Cite
|
Sign up to set email alerts
|

Effect of high-intensity exercise on cerebral, respiratory and peripheral muscle oxygenation of HF and COPD-HF patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(18 citation statements)
references
References 28 publications
3
14
0
Order By: Relevance
“…The skinfold was < 12.5 mm in all patients to ensure that the amount of fat between the muscle probe did not interfere with the signals ( van der Zwaard et al, 2016 ). The light probe was placed to the belly of the vastus lateralis muscle, approximately 15 cm from the upper edge of the patella, and firmly attached to the skin using adhesive tape ( Goulart et al, 2020b ) and involved in a black closed mesh with a velcro. Briefly, one fiberoptic bundle carries the NIR light produced by the laser diodes to the tissue of interest while a second fiberoptic bundle returns the transmitted light from the tissue to a photon detector in the spectrometer.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The skinfold was < 12.5 mm in all patients to ensure that the amount of fat between the muscle probe did not interfere with the signals ( van der Zwaard et al, 2016 ). The light probe was placed to the belly of the vastus lateralis muscle, approximately 15 cm from the upper edge of the patella, and firmly attached to the skin using adhesive tape ( Goulart et al, 2020b ) and involved in a black closed mesh with a velcro. Briefly, one fiberoptic bundle carries the NIR light produced by the laser diodes to the tissue of interest while a second fiberoptic bundle returns the transmitted light from the tissue to a photon detector in the spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…Due to the uncertainty of the differential pathlength factor (DPF) for the quadriceps, we did not use a DPF in the present study. The distance between the light emitters and the receiver was 3.5 cm ( Goulart et al, 2020b ).…”
Section: Methodsmentioning
confidence: 99%
“…(2) peak oxygen consumption ( VO 2 ) (in ml/min and mlO 2 kg −1 min −1 ); (3) carbon dioxide production VCO 2 (ml/min); (4) minute ventilation peak ( VE ) (ml/min); 5) WR (W); (6) HR at rest and peak (bpm); (7) peak peripheral oxygen saturation (SpO 2 , %); and (8) Borg dyspnea and leg effort 0-10. The VO 2 (in ml/min and mlO 2 kg −1 min −1 ), VCO 2 (ml/min), and VE (ml/min) were reported as 20-s averaged data.…”
Section: Ventilatory Metabolic Cardiac and Hemodynamic Measurementsmentioning
confidence: 99%
“…Transmitter light and receiver fiber were separated by 40 mm, corresponding to ∼20 mm of penetration depth. This method allows dynamic evaluation of relative blood concentration changes of oxyhemoglobin (OxyHb+Mb) and deoxyhemoglobin (DeoxyHb+Mb) (7).…”
Section: Near-infrared Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation