Effect of halide ions on passivation and pitting Corrosion of copper in alkaline solutions

Abstract: The passivity of copper in NaOH and borate buffer solutions wntainingcbloride, bromide and fluoride ions was studied by using cyclic voltammetry and potentiostatic current transient measurements. At scan rates 3 20 mVs-*, the addition of halide ions does not nearly affect the cyclic voltammograms in the absence of pitting. But they differ considerably in presence of pitting. The pitting potential was found to depend on the solution pH and decreased linearly with increase of logarithm of halide ion concentratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0

Year Published

1994
1994
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 40 publications
(1 reference statement)
1
9
0
Order By: Relevance
“…This promising property is worth further exploration. Among other nitrogen containing inhibitors of copper corrosion, studied so far, are derivatives of pyrazole [44,45], benzo-hydroxamic acid [46], and secondary amines [47]. The inhibition of copper corrosion in sodium chloride solutions with piperidine derivatives was also studied [48,49].…”
Section: Introductionmentioning
confidence: 99%
“…This promising property is worth further exploration. Among other nitrogen containing inhibitors of copper corrosion, studied so far, are derivatives of pyrazole [44,45], benzo-hydroxamic acid [46], and secondary amines [47]. The inhibition of copper corrosion in sodium chloride solutions with piperidine derivatives was also studied [48,49].…”
Section: Introductionmentioning
confidence: 99%
“…Owing to the residual O2 in the tunnel and upper bentonite blocks, the canister top surface may be more prone to pitting corrosion in Cl − solutions. However, the corrosion potentials is below −0.29 VSCE were considerably lower than the pitting corrosion potentials in the range 0.4-0.9 VSCE (corresponding to pHs in the range 7.26-9.24) for the 0.1 M Cl − solution [40]. Moreover, as can be seen in Figure , between 2 and 10 years, copper is corroded and form Cu2S rather than CuCl2 -.…”
Section: Possibility Of Local Corrosionmentioning
confidence: 85%
“…However, localized corrosion processes can occur under aerated conditions in the presence of aggressive anions, or when the pH of the solution is increased. Many studies have been performed to investigate the pitting of Cu in a range of environments, with corrosion parameters considered to be deterministic, not distributed 18,22,26,27,29,31,54,[65][66][67] . However, we showed the stochastic nature of corrosion parameters in our previous papers 73 .…”
Section: Introductionmentioning
confidence: 99%
“…The Cu2O is commonly porous, allowing Cu 2+ ions to diffuse into solution and precipitate to form an outer layer of CuO or/and Cu(OH)2. The properties of this double-layer film on the Cu surface depend on the pH of the solution 12,17,[30][31][32] .…”
Section: Introductionmentioning
confidence: 99%