2012
DOI: 10.1016/j.toxlet.2012.03.261
|View full text |Cite
|
Sign up to set email alerts
|

Effect of GST polymorphisms on As levels of placental and maternal biological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0
2

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 0 publications
0
4
0
2
Order By: Relevance
“…The method developed by Aliyev et al in 2012 was used for preparing the samples for analysis . One milliliter of amniotic fluid samples was placed into high‐temperature‐resistant Teflon tubes in a microwave oven, and 5 mL Suprapur (Merck, Darmstadt, Germany) nitric acid (HNO 3 ) and 5 mL ultrapure water were added.…”
Section: Methodsmentioning
confidence: 99%
“…The method developed by Aliyev et al in 2012 was used for preparing the samples for analysis . One milliliter of amniotic fluid samples was placed into high‐temperature‐resistant Teflon tubes in a microwave oven, and 5 mL Suprapur (Merck, Darmstadt, Germany) nitric acid (HNO 3 ) and 5 mL ultrapure water were added.…”
Section: Methodsmentioning
confidence: 99%
“…For lead analysis we took 1 mL of the whole blood sample, placed in a Teflon tube, added 5 mL of suprapuregrade 65% nitric acid (HNO 3 , Merck, Darmstadt, Germany) and 5 mL of ultrapure water (Millipore Direct-Q3, Merck), and digested in a Milestone Start D microwave digestion system (Sorisole, Italy). The digested samples were then transferred to 50 mL polypropylene tubes, added deionised to obtain the total volume of 20 mL, and stored at +4 °C until analysis (26). Lead levels were determined with inductively coupled plasma mass spectrometry (ICP-MS; iCAP Qc model, Thermo Scientific, Waltham, MA, USA).…”
Section: Collection Of Biological Samples and Laboratory Analysismentioning
confidence: 99%
“…The samples were transferred to 50 mL polypropylene tubes, and the total volume was completed to 20 mL with ultrapure water. 17 The selenium levels of the digested samples in the microwave system were determined by the Inductively Coupled Plasma- Mass Spectrometry (ICP-MS) system; Thermo Scientific ICAP QC, USA). The operating parameters were set as follows: RF power 1550 W, nebulizer gas 0.90 L/min, plasma gas 0.80 L/min, nebulizer pressure 3.00 bar, dwell time 0.01, and spray chamber temperature 2.7 °C.…”
Section: Methodsmentioning
confidence: 99%