Abstract: The effect of frequency of alternating current during ohmic heating on electrode corrosion, heating rate, inactivation of foodborne pathogens, and quality of salsa was investigated. The impact of waveform on heating rate was also investigated. Salsa was treated with various frequencies (60 Hz to 20 kHz) and waveforms (sine, square, and sawtooth) at a constant electric field strength of 12.5 V/cm. Electrode corrosion did not occur when the frequency exceeded 1 kHz. The heating rate of the sample was dependent o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
27
0
6

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 66 publications
(40 citation statements)
references
References 26 publications
(28 reference statements)
1
27
0
6
Order By: Relevance
“…This result is similar to those of other research studies (Lee et al, , 2013Leizerson & Shimoni, 2005). In conclusion, we confirmed that ohmic heating technology achieved more effective inactivation of food-borne pathogens in orange juice when combined with higher acidity without damaging quality.…”
Section: Discussionsupporting
confidence: 95%
See 1 more Smart Citation
“…This result is similar to those of other research studies (Lee et al, , 2013Leizerson & Shimoni, 2005). In conclusion, we confirmed that ohmic heating technology achieved more effective inactivation of food-borne pathogens in orange juice when combined with higher acidity without damaging quality.…”
Section: Discussionsupporting
confidence: 95%
“…Because these two organisms are most difficult to control, by inactivating them, other pathogenic organisms will also likely be controlled (US FDA, 1998). We used a voltage frequency of 20 kHz because no electrochemical reactions e which can cause electrode corrosion during ohmic heating occur at that frequency (Lee, Ryu, and Kang, 2013;Park & Kang, 2013). When using ohmic heating, heating rates differed for each pH level because added salts necessary for adjusting pH caused samples to have different electric conductivity.…”
Section: Discussionmentioning
confidence: 99%
“…Note the advantag es of using ohmic heating to pasteurize skim milk and cream: (i) ohmic heating can increase temperature much more rapidly than conventional heating and (ii) quality parameters were degraded less by ohmic heating than by conventional heating. Because electrode corrosion is a factor that limits widespread application of ohmic heating (9), further study will be needed to investigate electrode coiTosion during ohmic heating used for dairy product pasteurization processing.…”
Section: Discussionmentioning
confidence: 99%
“…Ohmic heating treatments were carried out in a previously described apparatus (9). The ohmic heating system ( Fig.…”
Section: Sample Preparation and Inoculationmentioning
confidence: 99%
“…In the present study, the sample pH was fixed at 7.2 using BPW to evaluate the effect of moderate electric fields to reduce food-borne pathogens without altering other conditions. Moreover, since electrochemical reactions, which produce chemicals affecting inactivation of food-borne pathogens, can occur at the standard line voltage frequency (60 Hz) during ohmic heating, 20 kHz, a high frequency that does not cause electrochemical reactions, was used in this study (28,29). Reductions of 2.42, 3.21, and 0.70 logs with treatment at 58°C for 30 s and reductions of 3.59, 3.48, and 3.40 logs with treatment at 60°C for 30 s in E. coli O157: H7, S. Typhimurium, and L. monocytogenes, respectively, were induced by ohmic heat electric fields.…”
Section: Discussionmentioning