2020
DOI: 10.1097/mao.0000000000002751
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Electrode to Modiolus Distance on Electrophysiological and Psychophysical Parameters in CI Patients With Perimodiolar and Lateral Electrode Arrays

Abstract: Objectives: To investigate the intracochlear position of the latest Cochlear Nucleus 532 electrode array compared with the straight Nucleus 522 and the precurved 512 arrays and determine the effect of the electrode–modiolus distance on electrically evoked compound action potential, C-levels, electrically evoked stapedius reflex thresholds (ESRTs), and impedances. Methods: Postoperative high-resolution cone beam computational tomography images of 30 pati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 15 publications
0
16
1
Order By: Relevance
“…3 a, b). However, this has been controversially discussed so far: whereas some groups observed NRT levels to be larger with increased distance to the modiolus [ 29 , 30 ], previous observations made by us and other groups revealed no significant differences [ 3 6 , 31 ].…”
Section: Discussionmentioning
confidence: 77%
“…3 a, b). However, this has been controversially discussed so far: whereas some groups observed NRT levels to be larger with increased distance to the modiolus [ 29 , 30 ], previous observations made by us and other groups revealed no significant differences [ 3 6 , 31 ].…”
Section: Discussionmentioning
confidence: 77%
“…Clinical imaging outcomes of electrode array in use within the first cochlear turn show distances in the range 0.60–1.67 mm (for Cochlear 532/632 array 0.80 ± 0.10 mm and for 512 array 0.76 ± 0.07 mm; data from Ref. 62 ). Closer locations, and thus true “modiolar hugging electrodes”, particularly those aiming at implantations beyond 400°, require new surgical and technical approaches due to the changing diameter of the modiolus.…”
Section: Discussionmentioning
confidence: 99%
“…10). Clinical imaging outcomes of electrode array in use within the first cochlear turn show distances in the range 0.60 -1.67 mm (for Cochlear 532/632 array 0.80±0.10 mm and for array 0.76±0.07 mm; data from 58 ). Closer locations, and thus true "modiolar hugging electrodes", particularly those aiming at implantations beyond 400°, require new surgical and technical approaches due to the changing diameter of the modiolus.…”
Section: Discussionmentioning
confidence: 99%