2019
DOI: 10.1213/ane.0000000000004102
|View full text |Cite|
|
Sign up to set email alerts
|

Effect of Dynamic Versus Stylet-Guided Intubation on First-Attempt Success in Difficult Airways Undergoing Glidescope Laryngoscopy: A Randomized Controlled Trial

Abstract: BACKGROUND: Tracheal intubation failure in patients with difficult airway is still not uncommon. While videolaryngoscopes such as the Glidescope offer better glottic vision due to an acute-angled blade, this advantage does not always lead to an increased success rate because successful insertion of the tube through the vocal cords may be the limiting factor. We hypothesize that combined use of Glidescope and fiberscope used only as a dynamic guide facilitates tracheal intubation compared to a conve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(26 citation statements)
references
References 34 publications
0
26
0
Order By: Relevance
“…The GlideScope's decreased working space and acute laryngeal entry angle compared with the MacIntosh laryngoscope has led to investigation of the "can see but can't intubate" situation. Case reports have suggested that the flexible tip of a videobronchoscope (fiberscope) can prevent ETT impingement on the trachea [14,15], and a prospective clinical trial showed that a flexible tip ETI (fiberscope) was superior to a preshaped stylet [6]. A comparison of the FROVA and the FTB with experienced intubators using the GlideScope showed faster and easier intubation with the FTB [7], and another manikin study using a MacIntosh laryngoscope showed superiority of the FTB during simulated cardiac arrest [16].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The GlideScope's decreased working space and acute laryngeal entry angle compared with the MacIntosh laryngoscope has led to investigation of the "can see but can't intubate" situation. Case reports have suggested that the flexible tip of a videobronchoscope (fiberscope) can prevent ETT impingement on the trachea [14,15], and a prospective clinical trial showed that a flexible tip ETI (fiberscope) was superior to a preshaped stylet [6]. A comparison of the FROVA and the FTB with experienced intubators using the GlideScope showed faster and easier intubation with the FTB [7], and another manikin study using a MacIntosh laryngoscope showed superiority of the FTB during simulated cardiac arrest [16].…”
Section: Discussionmentioning
confidence: 99%
“…Alternatively, some ETIs have a flexible tip replicating the action of a flexible bronchoscope (fiberscope) tip. When a fiberscope is used by experienced intubators as a "dynamic introducer", it is superior to a stylet in difficult GlideScope intubation [6].…”
Section: Introductionmentioning
confidence: 99%
“…With difficult airways, the FOB is often used as a "smart stylet" [8] to introduce an ETT directly into the 2 Case Reports in Anesthesiology trachea while the VL is used to visualize the glottic opening. One randomized controlled clinical trial was able to determine the superiority of a combined VL/FOB technique in successful intubation on first attempt, quicker intubation times, and less injury during intubation [9]. e utility of this combined approach in trauma patients with facial fractures has also been described [10].…”
Section: Discussionmentioning
confidence: 99%
“…It is found that the Flexible Tip Bougie provided a faster time to intubation and a greater ease of use than the FROVA [ 2 ]. A recent clinical trial with expected difficult intubations and a videolaryngoscope plus a flexible bronchoscope being used as a tube introducer demonstrated superiority with respect to first pass success, time to intubation, and airway trauma compared with a videolaryngoscope using a preshaped nondynamic stylet-guided endotracheal tube [ 3 ]. We feel that our patient may have been more difficult to intubate with a stylet-guided endotracheal tube as the available glottic visibility was significantly reduced by the large tumor.…”
Section: Discussionmentioning
confidence: 99%