“…The research by Carneiro R. A et al showed that the banded structure of pipeline steel reduces its HIC and SSC resistance [9][10][11][12][13][14]. The influence of different microstructures on the properties of V150 drill pipe was studied by [15]. It is concluded that the banded microstructure and inclusions in the V150 drill pipe steel are the key factors leading to HIC.…”
Section: Influence Of Banded Structure On the Performance Of Petroleu...mentioning
The influence of banded structure on the performance of petroleum pipe was introduced firstly, and the characteristics and application scope of different rating methods of banded structure studied, and the banded structure in different specimens rated using this standards/methods. The banded structure rating of petroleum pipe steel requires proper and reasonable standards/methods for different microstructures. The current standards/methods could not integrate standard diagram comparison with calculation, and can not cover the banded structure rating for all pipeline steel microstructures. Therefore, in order to satisfy the inspection needs of petroleum pipe steel, a new rating standard is required to be established.
“…The research by Carneiro R. A et al showed that the banded structure of pipeline steel reduces its HIC and SSC resistance [9][10][11][12][13][14]. The influence of different microstructures on the properties of V150 drill pipe was studied by [15]. It is concluded that the banded microstructure and inclusions in the V150 drill pipe steel are the key factors leading to HIC.…”
Section: Influence Of Banded Structure On the Performance Of Petroleu...mentioning
The influence of banded structure on the performance of petroleum pipe was introduced firstly, and the characteristics and application scope of different rating methods of banded structure studied, and the banded structure in different specimens rated using this standards/methods. The banded structure rating of petroleum pipe steel requires proper and reasonable standards/methods for different microstructures. The current standards/methods could not integrate standard diagram comparison with calculation, and can not cover the banded structure rating for all pipeline steel microstructures. Therefore, in order to satisfy the inspection needs of petroleum pipe steel, a new rating standard is required to be established.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.