2017
DOI: 10.1080/00015385.2017.1291181
|View full text |Cite
|
Sign up to set email alerts
|

Effect of dobutamine stress echocardiography on serum heart fatty acid binding protein levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 18 publications
1
2
0
Order By: Relevance
“…Therefore, it seems advisable to combine H-FABP testing with another, more specific biomarker or another test for CAD, such as stress echocardiography. This was confirmed in a recent study by Akinci et al where serum H-FABP levels increased significantly at 1 h in the presence of ischemia induced by dobutamine stress echocardiography in patients with stable clinical coronary syndromes [34]. As the authors pointed out, adding H-FABP measurements to pharmacologic stress tests may improve their diagnostic accuracy.…”
Section: Heart-type Fatty Acid Binding Protein (H-fabp)supporting
confidence: 55%
“…Therefore, it seems advisable to combine H-FABP testing with another, more specific biomarker or another test for CAD, such as stress echocardiography. This was confirmed in a recent study by Akinci et al where serum H-FABP levels increased significantly at 1 h in the presence of ischemia induced by dobutamine stress echocardiography in patients with stable clinical coronary syndromes [34]. As the authors pointed out, adding H-FABP measurements to pharmacologic stress tests may improve their diagnostic accuracy.…”
Section: Heart-type Fatty Acid Binding Protein (H-fabp)supporting
confidence: 55%
“…The authors concluded that cTn-I remained the best single test, with the incremental diagnostic sensitivity of serum H-FABP, but not copeptin. Furthermore, a recent dobutamine stress echocardiography (DSE) study reported significantly increased levels of serum H-FABP at 1 hour in the presence of DSE-induced ischemia, in contrast to DSE negative group, whose serum H-FABP remained unchanged before and 1 hour after the test 24 . However, in a study that was expected H-FABP to increase during exercise stress testing (EST), serum H-FABP tended to decline statistically significant from the basal level to 3 hours after the EST 25 .…”
Section: Discussionmentioning
confidence: 99%
“…A detectable level is reached in the initial period of myocardial necrosis, which means that H-FABP is a sensitive and reliable biomarker that can be used for the early detection of myocardial injury. In patients with perioperative myocardial infarction (PMI), the level of H-FABP is high and it can be used as an earlier telltale sign than the cTnI biomarker to differentiate between patients with and without perioperative myocardial infarction one hour after CABG, compared to increased cTnI levels after about 12 h [ 6 ].…”
Section: Introductionmentioning
confidence: 99%