2011
DOI: 10.1016/j.dental.2010.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Effect of denture cleansers on chemical and mechanical behavior of selected soft lining materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
61
1
3

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(75 citation statements)
references
References 15 publications
5
61
1
3
Order By: Relevance
“…SEM analyses revealed that the acrylic based material showed the greatest amount of surface irregularities, confirming Ra test results. SEM analysis showed higher damages on the surface materials when sodium perborate and 0.5% NaOCl were used, as previously demonstrated 12,14 . No differences among groups were observed considering sorption and solubility tests, suggesting that the materials tested appear to have the same performance before and after the treatments, as observed in other studies 11 .…”
Section: Discussionsupporting
confidence: 57%
See 1 more Smart Citation
“…SEM analyses revealed that the acrylic based material showed the greatest amount of surface irregularities, confirming Ra test results. SEM analysis showed higher damages on the surface materials when sodium perborate and 0.5% NaOCl were used, as previously demonstrated 12,14 . No differences among groups were observed considering sorption and solubility tests, suggesting that the materials tested appear to have the same performance before and after the treatments, as observed in other studies 11 .…”
Section: Discussionsupporting
confidence: 57%
“…In this context, the mechanical properties assessment is important since higher Ra could result in higher biofilm formation, consequently increasing the potential to develop biofilm-based diseases and it is usually not tested in microbiological studies 6,13 . In this study, Ra was not affected by the treatments, although there are reports in the literature showing damage caused by NaOCl 14 . However, NaOCl was used in a low concentration (0.5%), which seems to present no detrimental effect on resilient denture liners.…”
Section: Discussionmentioning
confidence: 37%
“…12,13,16 Bu nedenle protez temizleyicilerinin seçiminde astar maddesinin kompozisyonu da göz önünde bulundurulmalıdır. 17,18 Dental materyaller için en önemli özelliklerden birisi renk stabilitesidir.…”
Section: Gġrġġunclassified
“…Bu bileĢiklerin salınımı materyallerin elastisitelerinde azalmaya sebep olmaktadır. 16 Bunun yanında plastikleĢtiricilerin, monomerlerin ve pigmentlerin salınımı da materyalde renk değiĢimine yol açabi-lir. 33,34 Akrilik rezin ve silikon esaslı yumuĢak astar maddelerinin renk stabiliteleri kıyaslandığında, silikon esaslı materyallerin daha yüksek renk stabilitesi gösterdiği belirtilmiĢtir.…”
Section: Tartiġmaunclassified
“…Tissue conditioners should not be cleaned by scrubbing with a hard brush in order to prevent tearing of the material [8]. The use of soft brush under running water is recommended.…”
Section: Care and Maintenancementioning
confidence: 99%