1999
DOI: 10.1155/1999/236068
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Dead Volume on the Efficiency and the Cost to Deliver Medications in Cystic Fibrosis with Four Disposable Nebulizers

Abstract: OBJECTIVES:To evaluate the factors that affect nebulizer efficiency and to compare the relative cost effectiveness of nebulized medications used in the treatment of cystic fibrosis (CF), delivered by four types of disposable jet nebulizers that are widely used in hospitals. DESIGN: The Hudson 1730 Updraft II, Baxter Misty-Neb, Marquest Whisper Jet (WJ), and Marquest Acorn II were evaluated in terms of respirable aerosol output (particles 5 µm or less), nebulizer dead (residual) volume (V D ), and time for comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2001
2001
2019
2019

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(17 citation statements)
references
References 37 publications
0
17
0
Order By: Relevance
“…Several current disposable nebulizers do create particle sizes below 5 μm, as measured by laser diffraction. 16 …”
Section: Relevance Of Water Particle Size and Depositionmentioning
confidence: 99%
“…Several current disposable nebulizers do create particle sizes below 5 μm, as measured by laser diffraction. 16 …”
Section: Relevance Of Water Particle Size and Depositionmentioning
confidence: 99%
“…Such information is frequently not available, making an appropriate choice of equipment difficult. 12 While most aerosol droplets in nature are formed by condensation of a supersaturated gas around a suspended nucleus, e.g., cloud formation, the production of droplets of medical aerosol involves a different mechanism. Basically, nebulization can be accomplished by ultrasonic or jet nebulization.…”
Section: Aerosol Administration Devicesmentioning
confidence: 99%
“…15,16 This places considerable physical demands on the equipment. Repetitive use of disposable devices in the laboratory can lead to degradation of the particle size distribution when the device is driven hard from a 50 psi source of compressed air 12 although, with the use of a compressor in the home environment, the clinical significance of this is questionable. 17,18 However, the plastic in disposable devices may not stand up to proper cleaning, and failure to adequately clean the device leads to significant bacterial contamination.…”
Section: Aerosol Administration Devicesmentioning
confidence: 99%
See 2 more Smart Citations