Effect of contact force modeling parameters on the system hydrodynamics of spouted bed using CFD-DEM simulation and 2 factorial experimental design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 64 publications
0
6
0
Order By: Relevance
“…The P-value is used to determine whether the main effects and interaction effects are significant. If P-value less than 0.05, the model parameters considered as significant (Yurata et al, 2020).…”
Section: Anova Results and Regression Modelmentioning
confidence: 99%
“…The P-value is used to determine whether the main effects and interaction effects are significant. If P-value less than 0.05, the model parameters considered as significant (Yurata et al, 2020).…”
Section: Anova Results and Regression Modelmentioning
confidence: 99%
“…The independent inputs with a p value lower than 0.05 at a confidence interval of 95% were identified as significant parameters, as shown in Table . In addition, the trends for different parameters are as plotted in Figure , which show the averaged values of each response at high and low levels of the considered input parameters …”
Section: Resultsmentioning
confidence: 99%
“…In addition, the trends for different parameters are as plotted in Figure 6, which show the averaged values of each response at high and low levels of the considered input parameters. 36 Figure 5a shows the standard deviations of the axial and radial solid volume fraction for the obtained simulation results. For the axial direction, the standard deviations of cases 1 to 4 and 9 to 12 had less value than the typical downer reactor case.…”
Section: Model Validationmentioning
confidence: 99%
“…When u g > U mt , the "characteristic curve" shows some fluctuations in the bed pressure drop, which come from the change in the kinetic energy of particles. Yurata et al 47 found that an increase in the translation kinetic energy reduces the height of the fountain zone, whereas a decrease in the rotation kinetic energy led to an increase in the fluctuations of bed pressure drop.…”
Section: Numerical Model Validation 421 Effect Of Contact Models On U Mfmentioning
confidence: 99%