1990
DOI: 10.1063/1.1141223
|View full text |Cite
|
Sign up to set email alerts
|

Effect of changes in viewing window transmission on high-temperature Thomson scattering data

Abstract: Unmonitored changes in the transmission of viewing windows owing to deposited films can produce errors in Thomson scattering temperature measurements. This effect is illustrated by a recent run on the Tokamak Fusion Test Reactor (TFTR) where apparent errors of over 25% in peak temperatures of 9 keV owing to carbon films were noted. Since coatings can also be removed by hydrogen discharges, the transmission of a window may change with time, resulting in variable errors in the temperature. It is proposed that th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
4
0
4

Year Published

1992
1992
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 11 publications
1
4
0
4
Order By: Relevance
“…The experimental data on the transmissivity of the films deposited on the windows of the Tokamak Fusion Test Reactor (TFTR) and the JT-60 under carbonization have been given in [69,70]. In both cases, the vessel walls were regularly coated by a carbon film.…”
Section: Introductionmentioning
confidence: 99%
“…The experimental data on the transmissivity of the films deposited on the windows of the Tokamak Fusion Test Reactor (TFTR) and the JT-60 under carbonization have been given in [69,70]. In both cases, the vessel walls were regularly coated by a carbon film.…”
Section: Introductionmentioning
confidence: 99%
“…The measured spectral transmission losses of a TFTR window [238] were found to be very similar to samples coated in laboratory glow [253] and ECR discharges in H 2 /CH 4 gas mixtures. Based on windows used in JT60-U during 1992-1995, a simple polynomial description for the wavelength dependent attenuation by a film of thickness d has empirically been derived [246].…”
Section: Contamination Of Diagnostic Windowsmentioning
confidence: 69%
“…Detailed investigations particularly into the chromatic transmission of predominantly hydrocarbon coated windows have been undertaken in the field of Thomson-scattering diagnostics since the wavelength dependence leads to significant errors in derived temperatures, but of course also density measurements [238,246]. The measured spectral transmission losses of a TFTR window [238] were found to be very similar to samples coated in laboratory glow [253] and ECR discharges in H 2 /CH 4 gas mixtures.…”
Section: Contamination Of Diagnostic Windowsmentioning
confidence: 99%
See 1 more Smart Citation
“…Для настройки многоканальных систем регистрации ТР применялись современные источники излучения, например, оптический параметрический генератор (ОПГ), перестраиваемый в широком диапазоне длины волны [4]. В работе [5] для определения пропускания оптического окна, используемого при измерении электронной температуры методом ТР, в качестве источника калибровочного излучения был применён тлеющий разряд в водороде при фиксированных условиях (рабочее давление газа, магнитное поле, напряжение разряда и др.). Применимость такого метода калибровки связана с воспроизводимостью спектра излучения используемого разряда.…”
Section: Introductionunclassified