2015
DOI: 10.1016/j.jfoodeng.2014.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Effect of changes in microwave frequency on heating patterns of foods in a microwave assisted thermal sterilization system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
18
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(21 citation statements)
references
References 14 publications
2
18
0
1
Order By: Relevance
“…The color changes in the gellan gel which reflect the distribution of M-2 and thermal lethality were detected using a computer vision method as described in Pandit et al (2007). Based on our system design, the configuration of the microwave heating system for each cavity is symmetrical in the thickness direction (vertical line), as a result the electric field distribution is symmetrical, where the middle layer of homogenous samples receives the least energy (Resurreccion, 2015). This is confirmed by our previous work (Luan et al, 2013(Luan et al, & 2015Tang et al, 2008;Zhang et al, 2014).…”
Section: Determination Of the Heating Pattern And Cold Spot In Samplesupporting
confidence: 68%
See 1 more Smart Citation
“…The color changes in the gellan gel which reflect the distribution of M-2 and thermal lethality were detected using a computer vision method as described in Pandit et al (2007). Based on our system design, the configuration of the microwave heating system for each cavity is symmetrical in the thickness direction (vertical line), as a result the electric field distribution is symmetrical, where the middle layer of homogenous samples receives the least energy (Resurreccion, 2015). This is confirmed by our previous work (Luan et al, 2013(Luan et al, & 2015Tang et al, 2008;Zhang et al, 2014).…”
Section: Determination Of the Heating Pattern And Cold Spot In Samplesupporting
confidence: 68%
“…2 it is also seen that the dielectric loss factor of carrot samples at each temperature matched well with the dielectric loss factor of gellan gel added with 40 mM NaCl calculated by the regression equations developed by Zhang et al (2015). The calculated dielectric constant values of gellan gel added with 40 mM NaCl fell within the range of ± 10% deviation of the real food's dielectric constants, and wouldn't change the heating pattern and cold spot location based on the computer simulation results (Resurreccion, 2015). Therefore, gellan gel (1% gellan gum, 6mM…”
Section: Dielectric Properties Of Carrot Samples and Selection Of Modsupporting
confidence: 68%
“…A major advantage of the design is stable heating patterns in foods over a wide range of food properties. Our recent studies show that variations in the peak frequency of microwaves within the FCC allocated frequency bandwidth (902 to 928 MHz) around 915 MHz do not influence heating patterns in the tested foods (Resurreccion and others 2015 ).…”
Section: Mhz Single-mode Microwave Sterilization Technology Develmentioning
confidence: 93%
“…Specific developments have also been simulated for sterilization processes [15]. In [16] a very high microwave power in a cylindrical cavity was employed to measure the effect of sterilization in a specific food sample.…”
Section: Introductionmentioning
confidence: 99%