2015
DOI: 10.1615/atomizspr.2015011919
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Assist-Air of Twin Fluid Atomizer on Urea Thermal Decomposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…An approximate measuring range (8–450 μm), measuring distance (within 400 mm, laser spot radius: 3.9 [pixel]), and CCD (EPIX CMOS camera) were used. SMD is measured 200 mm downstream from the tip of the nozzle (tip). The spray image was taken using an ultra-high-speed camera (Phantom VEO E310L, maximum resolution: 512 × 512; sample rate: 11,500 f/s) and a stroboscope for the visualization of the spray from the nozzle. More than 300 images were analyzed for each experimental condition and taken after the spray pattern reaching a static state under each spray condition.…”
Section: Experimental Setup and Methodsmentioning
confidence: 99%
“…An approximate measuring range (8–450 μm), measuring distance (within 400 mm, laser spot radius: 3.9 [pixel]), and CCD (EPIX CMOS camera) were used. SMD is measured 200 mm downstream from the tip of the nozzle (tip). The spray image was taken using an ultra-high-speed camera (Phantom VEO E310L, maximum resolution: 512 × 512; sample rate: 11,500 f/s) and a stroboscope for the visualization of the spray from the nozzle. More than 300 images were analyzed for each experimental condition and taken after the spray pattern reaching a static state under each spray condition.…”
Section: Experimental Setup and Methodsmentioning
confidence: 99%
“…The flow rate and pressure data in this experiment are the averages of sampling at 100 Hz for 10 s. , The spray image of the Y-jet nozzle was recorded by attaching a high-speed camera (Phantom VEO E310L, maximum resolution: 512 × 512, sample rate: 11,500 f/s) to the front of the nozzle and a light source to the back. Spray images were collected more than 500 times per experimental condition after ensuring that the spray pattern had attained a static state based on the spray conditions.…”
Section: Methodsmentioning
confidence: 99%
“…35 The SMD and SMD standard deviation were measured using Malvern's Spraytech (MLXA-A12-635-5) based on the line of sight principle. 38 4.4. Experimental Conditions.…”
Section: Solution Stirring Methods and Measurement Of Propertiesmentioning
confidence: 99%