2014
DOI: 10.4028/www.scientific.net/amm.493.74
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Air Conditioning Position on Thermal Comfort in the Floor Air Conditioning System

Abstract: Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixtur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 7 publications
(8 reference statements)
0
9
0
Order By: Relevance
“…A good air conditioning system is needed to save energy in addition to getting a comfortable room with good air distribution and a comfortable air temperature and appropriate flow rate in a room. This is what has led many researchers to investigate the performance of HVAC [1,[9][10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…A good air conditioning system is needed to save energy in addition to getting a comfortable room with good air distribution and a comfortable air temperature and appropriate flow rate in a room. This is what has led many researchers to investigate the performance of HVAC [1,[9][10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…However, according to [25], floor air conditioning (FAC) is more energy-efficient and is in growing demand. The problem with FAC is draft discomfort because the supply air is closer to the occupants.…”
Section: How Is It Calculated?mentioning
confidence: 99%
“…The problem with FAC is draft discomfort because the supply air is closer to the occupants. Different locations for the FAC in a residential unit is assessed by [25], and it is recommended that the outlets be located as far from occupants as possible to reduce draft discomfort. According to [24], floor air condition can achieve the best performance with a 45° deflection angle on a 1.1m sill, with an optimum supply velocity of 2.2m/s -3 m/s.…”
Section: How Is It Calculated?mentioning
confidence: 99%
“…Typically, thermal comfort can affect the worker's perception rates, productivity, and health [8][9][10]. Based on ASHRAE Standard 55 [11], "thermal comfort is the condition of mind which expresses satisfaction with the thermal environment".…”
Section: Introductionmentioning