1995
DOI: 10.1016/0042-207x(94)00149-9
|View full text |Cite
|
Sign up to set email alerts
|

Effect of a pre-filter on the sensitivity of a highresolution quadrupole mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1997
1997
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…4 and 9). This concept can easily be extended to more complex features such as Einzel lenses as well as prefilters and postfilters to improve performance [74], [75]. A simple change in the mask layout can be used to produce these additional features.…”
Section: Discussionmentioning
confidence: 99%
“…4 and 9). This concept can easily be extended to more complex features such as Einzel lenses as well as prefilters and postfilters to improve performance [74], [75]. A simple change in the mask layout can be used to produce these additional features.…”
Section: Discussionmentioning
confidence: 99%
“…Such an arrangement has been found to decrease fringing fields around the quadrupole entrance and exit apertures, thus helping to increase ion throughput. 29 The filters can also be used as lens elements by applying a small DC voltage that is isolated from the RF potential via high-voltage blocking resistors. The entire rod system is mounted inside a stainless steel canister that is held at ground potential.…”
Section: Methodsmentioning
confidence: 99%
“…The filters are inductively coupled to the RF from the main rod system. Such an arrangement has been found to decrease fringing fields around the quadrupole entrance and exit apertures, thus helping to increase ion throughput . The filters can also be used as lens elements by applying a small DC voltage that is isolated from the RF potential via high-voltage blocking resistors.…”
Section: Methodsmentioning
confidence: 99%
“…A number of investigations [2][3][4][5][6][7][8][9] have subsequently been made into the effects of the fringe fields of quadrupole mass analysers, with special reference to prefilters. [10][11][12][13] A computer model has been written to enable the further study of quadrupole mass spectrometer behaviour, with particular reference to three-dimensional ion trajectories, both within the main filter and the entrance fields, including the effects of z-energy changes in the latter. Assessments of acceptance areas have been made from determination of successfully transmitted ion trajectories.…”
mentioning