2004
DOI: 10.1016/j.clinph.2004.06.023
|View full text |Cite
|
Sign up to set email alerts
|

EEG dipole source localisation of interictal spikes acquired during routine clinical video-EEG monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…High electrode densities (≥64 channels) and extensive spatial coverage, including inferior temporal electrodes, increase the precision of ESI (Kobayashi et al., 2003; Lantz et al., 2003a; Meckes‐Ferber et al., 2004; Sperli et al., 2006). Fast neurophysiologic propagation affects the localization and morphology of scalp IED (Alarcon et al., 1994; Fernandez Torre et al., 1999) and ESI is more accurate when applied to the IED rising phase rather than to its peak (Lantz et al., 2003b).…”
Section: Eeg Source Imaging (Esi)mentioning
confidence: 99%
“…High electrode densities (≥64 channels) and extensive spatial coverage, including inferior temporal electrodes, increase the precision of ESI (Kobayashi et al., 2003; Lantz et al., 2003a; Meckes‐Ferber et al., 2004; Sperli et al., 2006). Fast neurophysiologic propagation affects the localization and morphology of scalp IED (Alarcon et al., 1994; Fernandez Torre et al., 1999) and ESI is more accurate when applied to the IED rising phase rather than to its peak (Lantz et al., 2003b).…”
Section: Eeg Source Imaging (Esi)mentioning
confidence: 99%
“…Increasing the number of electrodes from 19 to 29 in one study increased EEG spike localization accuracy from 36 to 93%. This, however, does not come as a surprise, because the extra electrodes covered the lower (temporal) part of the head and the endpoint was identification of the lobe of seizure onset, usually the temporal lobe [19]. In identifying a lobe, even with 21 electrodes, EEG can have an 85% concordance with MEG [43].…”
Section: Clinical Studies: Magnetoencephalography Versus Electroencepmentioning
confidence: 99%
“…Subtemporal electrodes have long been incorporated in the ESI of temporal spikes (Ebersole and Wade, 1990;Meckes-Ferber et al, 2004) and in the ESI of seizures (Kobayashi et al, 2000). They have been reported to significantly increase accuracy of temporal spike ESI (Ebersole, 1997) even with dense electrode arrays (Sperli et al, 2006).…”
Section: Discussionmentioning
confidence: 99%