Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration, operation, improvements

Abstract: The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the cor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 7 publications
0
11
0
Order By: Relevance
“…Since the beginning, it was designed to have two separate collection optics (both sharing one laser beam); one observing the edge plasma -1 - region with high resolution (~a/100), the second extending the measured profiles to the middle of the plasma. The first measurements used only the core TS lens, the edge lens was installed later [9]. Couple of modifications and upgrades were done on the system since its installation.…”
Section: Overview Of the Thomson Scattering Diagnostic On The Compass...mentioning
confidence: 99%
See 2 more Smart Citations
“…Since the beginning, it was designed to have two separate collection optics (both sharing one laser beam); one observing the edge plasma -1 - region with high resolution (~a/100), the second extending the measured profiles to the middle of the plasma. The first measurements used only the core TS lens, the edge lens was installed later [9]. Couple of modifications and upgrades were done on the system since its installation.…”
Section: Overview Of the Thomson Scattering Diagnostic On The Compass...mentioning
confidence: 99%
“…The available port for the edge TS was directed to the core plasma (figure 2), which made the optical design of the collection lens challenging [9]. The resulting edge TS system worked, but the available field of view proved to limit the variability of plasma scenarios to only those, where the pedestals were well covered.…”
Section: Edge Ts Portmentioning
confidence: 99%
See 1 more Smart Citation
“…COMPASS is equipped with a set of high resolution diagnostics for measurements in the plasma edge [13]. The most important one for these studies is the high resolution Thomson scattering (HRTS) [14,15], which allows to measure the edge profiles with a spatial resolution of ~2-3 mm (~a minor /100), which is sufficient to well resolve the pedestal. HRTS uses two 1.5 J Nd:YAG lasers with a repetition rate of 30 Hz each.…”
Section: The Compass Tokamakmentioning
confidence: 99%
“…Compass-D, Alcator C-Mod, T-10, Globus-M, START, RTP, TEXT, TJ-2, Uragan-2M, Uragan-3 and others have (or had) extended research programmes, wellequipped with sophisticated diagnostics and powerful heating systems. Figure 3 shows results from very advanced Thomson scattering diagnostics on COMPASS, IPP-AS Prague [30,31], and comparison of Thompson scattering (TS) measurements with very high core and edge resolution with reflectometry and Langmuir probes (LPs). Similar diagnostics on C-Mod, T-10 and Globus-M allows detailed investigation of the tokamak transport.…”
Section: Contribution To the Mainstream Fusion Researchmentioning
confidence: 99%