1993
DOI: 10.1016/0168-9002(93)90854-b
|View full text |Cite
|
Sign up to set email alerts
|

EDEN: a neutron time-of-flight multidetector for decay studies of giant states

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
32
0

Year Published

1994
1994
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(33 citation statements)
references
References 11 publications
1
32
0
Order By: Relevance
“…The determination of the incident neutron energy on the 238 U samples thus relies on the simulation of the inverse kinematics inside the hydrogen gas target, which has been implemented in GEANT4, and a subsequent validation using a neutron TOF measurement at 1.5 meters from the LICORNE source. A cylindrical NE213 liquid scintillation detector from the EDEN array [18] was used to perform such measurements. The neutron spectra seen by the samples were simulated for each inverse kinematics reaction and were validated by a comparison between simulated and measured TOF spectra, see Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The determination of the incident neutron energy on the 238 U samples thus relies on the simulation of the inverse kinematics inside the hydrogen gas target, which has been implemented in GEANT4, and a subsequent validation using a neutron TOF measurement at 1.5 meters from the LICORNE source. A cylindrical NE213 liquid scintillation detector from the EDEN array [18] was used to perform such measurements. The neutron spectra seen by the samples were simulated for each inverse kinematics reaction and were validated by a comparison between simulated and measured TOF spectra, see Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The performances of the pulse-shape discrimination technique of the module discussed above have been tested using NE213 scintillators of the EDEN (Etude de DEcroissances par Neutrons) detector array [18].…”
Section: In-beam Performancesmentioning
confidence: 99%
“…A detailed description of the detector layout and photomultipliers is given in Ref. [18]. The used high voltage power supply is a CAEN SY1527 system housing 36 independent channels arranged in 12 channel CAEN 1835 N boards.…”
Section: In-beam Performancesmentioning
confidence: 99%
“…The adopted module geometry is identical to that of the MONSTER spectrometer [2] and is similar to the EDEN array [3]. It is based on a BC501A liquid scintillator cell with a diameter of 20 cm and a depth of 5 cm, viewed by a 13 cm photomultiplier tube through a light guide.…”
Section: Development Strategiesmentioning
confidence: 99%