2002
DOI: 10.1029/2001jd000520
|View full text |Cite
|
Sign up to set email alerts
|

Eddy covariance measurements of nitric oxide flux within an Amazonian rain forest

Abstract: [1] NO flux measurements by the eddy covariance technique were performed within a tropical rain forest 1 m and 11 m above the forest floor. A fast-response chemiluminescence NO analyzer with a sampling tube of 25 m length was used for the gas measurements. Nighttime similarity between the cospectra of sensible heat and the NO flux offered the possibility to quantify the high-frequency attenuation of the NO eddy covariance by spectral analysis. Integrated flux correction factors of about 21% for the system at 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
90
0
6

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 109 publications
(105 citation statements)
references
References 48 publications
5
90
0
6
Order By: Relevance
“…Thus the potential for within-canopy oxidation, measurement height above the canopy, and other factors affecting canopy and atmospheric NO x levels to affect the observed NO, NO 2 and O 3 fluxes. This flux divergence has been observed in an Amazonian rain forest, where NO emissions from the soil were observed near the surface, but were not significant above the canopy (Rummel et al, 2002). NO x fluxes are further complicated by direct leaf exchange that may lead to the presence of a compensation point.…”
Section: Introductionmentioning
confidence: 98%
See 2 more Smart Citations
“…Thus the potential for within-canopy oxidation, measurement height above the canopy, and other factors affecting canopy and atmospheric NO x levels to affect the observed NO, NO 2 and O 3 fluxes. This flux divergence has been observed in an Amazonian rain forest, where NO emissions from the soil were observed near the surface, but were not significant above the canopy (Rummel et al, 2002). NO x fluxes are further complicated by direct leaf exchange that may lead to the presence of a compensation point.…”
Section: Introductionmentioning
confidence: 98%
“…EC flux measurements of NO y , NO, and NO 2 fluxes have been reported (e.g. Delany et al, 1986, Horii et al, 2004Munger et al, 1996;Rummel et al, 2002). Most other studies of N fluxes have used enclosure or indirect estimation techniques, including gradient measurements or resistance modeling (Hanson and Lindberg, 1991;Wesely and Hicks, 2000).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As O 3 is completely destroyed in the TRANC (thermal decomposition and reduction by CO), chemical NO loss by gas phase reaction (NO + O 3 → NO 2 + O 2 ) could also be neglected. Even if a small amount of O 3 would pass the TRANC, the influence on concentration changes are expected to be lower than the detection limit of the CLD according to Rummel et al (2002). A schematic overview of the TRANC-CLD system in an ECsetup is given in Fig.…”
Section: Combination Of Tranc With Fast-response No Analysismentioning
confidence: 99%
“…It generates electronically excited NO * 2 molecules, which rapidly decay to their ground state in a reduced pressure regime by emitting photons. The total light intensity in the reaction chamber, detected by a photomultiplier tube (PMT), is proportional to the NO mixing ratio (Fontijn et al, 1970;Rummel et al, 2002). To minimise electrical noise, the Fig.…”
Section: Combination Of Tranc With Fast-response No Analysismentioning
confidence: 99%