2021
DOI: 10.1016/j.energy.2020.119217
|View full text |Cite
|
Sign up to set email alerts
|

Eco-energetic feasibility study of using grid-connected photovoltaic system in wastewater treatment plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(5 citation statements)
references
References 50 publications
0
3
0
Order By: Relevance
“…In addition, the signal is sampled at every h time increment, so that the whole signal y(t) is described by the vector Y ∈ R N that contains the N data points of the given signal, as shown in Equation (2).…”
Section: Regression-based Fourier Model Formulationmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the signal is sampled at every h time increment, so that the whole signal y(t) is described by the vector Y ∈ R N that contains the N data points of the given signal, as shown in Equation (2).…”
Section: Regression-based Fourier Model Formulationmentioning
confidence: 99%
“…Solar energy has been widely adopted and integrated into various sectors, such as the gas and oil industries, where solar energy has evolved into a primary source for essential utilities, including applications in water treatment [1][2][3]. Accurate direct average irradiance data is necessary for commercial and residential solar panel installations.…”
Section: Introductionmentioning
confidence: 99%
“…No one doubts the necessity of wastewater treatment due to its high amount of physical, chemical, and biological pollution which is only reachable through treatment plants. However, the high costs of these large-scale projects have led experts Citation: Gheibi to fi nd the most appropriate process that, besides meeting quality parameters, optimally satisfi es the technical, economic, and environmental goals [12][13][14][15][16]. On the other hand, each of these treatment plants and related processes has special characteristics and attitudes.…”
Section: Introductionmentioning
confidence: 99%
“…The optimization proposed by authors is based on: energy balance, installation surface area and levelized cost of energy (LCOE). Obtained results show that the grid-connected PV system can cover 53% of WWTP electrical load and can inject 510 MWh/year into the grid, representing 65% of the load [18].…”
Section: Introductionmentioning
confidence: 99%