2018
DOI: 10.12669/pjms.346.15792
|View full text |Cite
|
Sign up to set email alerts
|

Echocardiography guided bed side balloon atrial septostomy in dextro transposed great arteries (dTGA) with intact ventricular septum (IVS): A resource limited country experience

Abstract: Objective:To determine effectiveness and safety of echocardiography guided bed side Balloon Atrial Septostomy (BAS) in dextro transposition of great Arteries (dTGA) with intact ventricular septum (IVS) at a public sector tertiary care hospital Karachi, Pakistan.Methods:This case series include 40 patients with echocardiographic findings of dTGA with IVS and restricted PFO (≤ 2mm) who underwent bedside BAS at department of pediatric cardiology NICVD, Karachi, Pakistan. We recorded pre and post BAS diameter of P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 14 publications
(14 reference statements)
0
3
0
Order By: Relevance
“…Registered complications were of mechanical (e.g., balloon rupture), traumatic (e.g., cardiac damage), embolic (e.g., cerebral event), and electrophysiological (e.g., transient rhythm disorders or AV‐block) nature and were reported for all catheters. The Fogarty and Miller‐Edwards balloon catheters were related with an increased frequency of balloon ruptures, whereas the Z‐5 and Rashkind catheters were not associated with this problem 5,12–14 …”
Section: Resultsmentioning
confidence: 99%
“…Registered complications were of mechanical (e.g., balloon rupture), traumatic (e.g., cardiac damage), embolic (e.g., cerebral event), and electrophysiological (e.g., transient rhythm disorders or AV‐block) nature and were reported for all catheters. The Fogarty and Miller‐Edwards balloon catheters were related with an increased frequency of balloon ruptures, whereas the Z‐5 and Rashkind catheters were not associated with this problem 5,12–14 …”
Section: Resultsmentioning
confidence: 99%
“…However, a number of complications have been reported as associated with this maneuver including balloon rupture with consequent embolization, air embolism, cardiac damage with rupture of the atrial appendage, mitral valve injury, vascular injury (of the pulmonary veins or the inferior vena cava), or thrombosis of the umbilical vein. [5][6][7][8][9][10][11][12][13][14]…”
Section: Results and Complicationsmentioning
confidence: 99%
“…The expected size of the atrial septal defect after interatrial stenting was around 5 mm. 8 The stent label size is always larger than the primary orifice or inside diameter of the stent. For this case, we used 6 mm stent diameter (one mm larger than the expected size) considering the stent struts' layer.…”
Section: Discussionmentioning
confidence: 99%