2019 IEEE EMBS International Conference on Biomedical &Amp; Health Informatics (BHI) 2019
DOI: 10.1109/bhi.2019.8834612
|View full text |Cite
|
Sign up to set email alerts
|

ECG Reconstruction via PPG: A Pilot Study

Abstract: In this paper, the relation between electrocardiogram (ECG) and photoplethysmogram (PPG) signals is studied, and the waveform of ECG is inferred via the PPG signals. In order to address this inverse problem, a transform is proposed to map the discrete cosine transform (DCT) coefficients of each PPG cycle to those of the corresponding ECG cycle. The resulting DCT coefficients of the ECG cycle are inversely transformed to obtain the reconstructed ECG waveform. The proposed method is evaluated on a benchmark data… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 29 publications
(37 citation statements)
references
References 10 publications
0
36
0
1
Order By: Relevance
“…Because of this close relationship, attempts have been made in previous studies to reconstruct ECG signals from the pulse wave signals of BF. [51] Although many external factors can affect the consistency between PRV and HRV, the physiological nature of BF and ECG signals leads to inevitable differences between them. One critical intrinsic factor is the pulse transit time, which is the time required for the blood to travel from the heart to the peripheral site where the BF is measured.…”
Section: 2mentioning
confidence: 99%
“…Because of this close relationship, attempts have been made in previous studies to reconstruct ECG signals from the pulse wave signals of BF. [51] Although many external factors can affect the consistency between PRV and HRV, the physiological nature of BF and ECG signals leads to inevitable differences between them. One critical intrinsic factor is the pulse transit time, which is the time required for the blood to travel from the heart to the peripheral site where the BF is measured.…”
Section: 2mentioning
confidence: 99%
“…In many studies, Sen and Spe are frequently used. From (8) and (9), it is known that the high Sen is equivalent to the low leakage rate of the AF detector, and the high Spe is equivalent to a low…”
Section: B Model With Hyperparametersmentioning
confidence: 99%
“…In addition, PPG has the same source of excitation (heart) as ECG. Zhu et al [9] also studied the relationship between ECG and PPG in 2019 and derived ECG waveforms using PPG. These studies show a strong correlation between ECG and PPG.…”
Section: Introductionmentioning
confidence: 99%
“…The method achieved a 90% accuracy on a benchmark hospital dataset having clean PPG signals. Furthermore, the authors in [106] proposed a signal model to linearly reconstruct the entire ECG from PPG waveforms. The method reached a subject-wise accuracy of 98% in averaged correlation on a benchmark dataset of subjects with different ages and weights.…”
Section: Future Directionsmentioning
confidence: 99%