Early Results of a New Rotating Hinge Knee Implant

Abstract: Background. Indication for rotating hinge (RH) total knee arthroplasty (TKA) includes primary and revision cases, with contradictory results. The aim of this study was to report prospective early results of a new modular rotating hinge TKA (EnduRo). For this implant several new design features and a new bearing material (carbon-fiber reinforced poly-ether-ether-ketone) have been developed. Furthermore, we tried to establish a new classification of failure modes for revision TKA. Methods. 152 EnduRo rotating-hi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
19
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(21 citation statements)
references
References 26 publications
2
19
0
Order By: Relevance
“…Furthermore the prosthesis provides an offset option for femoral and tibial stems. Cemented and cementless stem fixation are both possible, whereas the epiphyseal fixation of the implant has to always be cemented [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore the prosthesis provides an offset option for femoral and tibial stems. Cemented and cementless stem fixation are both possible, whereas the epiphyseal fixation of the implant has to always be cemented [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…Radiographic analysis included assessment of alignment and signs of loosening (radiolucent lines, osteolysis, PE wear, and implant migration). Furthermore, we evaluated complications leading to revision surgery of the involved knee and differentiated between three different types of complications as previously described [ 20 ]: type 1, PJI; type 2, periprosthetic complications such as failure of the extensor mechanism, periprosthetic fractures, patella failure, and wound dehiscence; type 3, implant complications like wear, aseptic loosening, instability, and implant failure (including breakage of axis, bushings, and stem). This particular differentiation originates from the observation that the implant has no or little influence on type 1 (septic) and type 2 (periprosthetic complications) failures, whereas type 3 failures are specifically linked to the prosthesis and therefore provide information about implant survival [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In 2014, Giurea et al analysed 152 EnduRo rotating hinge prostheses (90 primary arthroplasties, 62 revisions). 44 Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), OKS and ROM were evaluated before surgery, three months post-operatively, 12 months post-operatively and annually thereafter. KSS, WOMAC, OKS and ROM showed significant improvements between the pre-operative and the follow-up evaluations.…”
Section: Indications For Rotating Hinge Prostheses For Revision Tkamentioning
confidence: 99%
“…The RHK design EnduRo® (Aesculap AG Tuttlingen, Germany) with flanges and bushings made of CFR-PEEK was clinically introduced in November 2008 and has already shown satisfying results [20]. Moreover, the biological activity in vivo of CFR-PEEK debris was reported to be comparable to PE debris [21, 22].…”
Section: Introductionmentioning
confidence: 99%