Early Prediction of Tumor Response: A Future Strategy for Optimizing Cancer Treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 57 publications
0
7
0
Order By: Relevance
“…Nevertheless, small discrepancies between the computational and experimental quantitative metrics are attributed to the location and size of the tumor and surrounding healthy tissues. We have also measured the qualitative evaluation of an augmented PET image generated by the DCGAN model and another solid tumor with the same order of size in breast lesion [ 59 ]. As indicated in Figure 6 g,h, the results are only shown for solid tumors, which have been cut circularly.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, small discrepancies between the computational and experimental quantitative metrics are attributed to the location and size of the tumor and surrounding healthy tissues. We have also measured the qualitative evaluation of an augmented PET image generated by the DCGAN model and another solid tumor with the same order of size in breast lesion [ 59 ]. As indicated in Figure 6 g,h, the results are only shown for solid tumors, which have been cut circularly.…”
Section: Resultsmentioning
confidence: 99%
“…Comparison between ( e ) a synthetic PET image generated by biomathematical modeling without implementing the DCGAN for a 2cm tumor and ( f ) another augmented PET image generated using DCGAN. ( g ) The solid tumor in panel ( f ) is also compared with ( h ) another image of solid tumor taken experimentally [ 59 ], showing excellent agreement in terms of quantitative assessments with SSIM and PSNR values and qualitative comparison of radiotracer uptake in solid tumor. SSIM and PSNR values are defined according to Equations (16) and (17), respectively.…”
Section: Figurementioning
confidence: 93%
“…Additionally, we observed that the current clinically used techniques for monitoring efficacy, such as FDG-PET or CT, are of limited use in the acute temporal setting. In some of the animals we actually noted a transient increase in FDG uptake, consistent with the flare response seen at the onset of chemotherapy as a result of increased glucose uptake by inflammatory cells and/or energy demand of the apoptosis process (59). Additionally, recent studies have indicated that the oncogene activation status can regulate the internalization of [ 18 F]FDG (60), which can further confound the results with such imaging techniques.…”
Section: Discussionmentioning
confidence: 76%
“…Imaging of specific biomarkers associated with cancer has been developed for earlier diagnosis of oncology patients. PET with 18 F‐fluorodeoxyglucose is a representative imaging technique that can image glucose metabolism of the tumor cells and thus can assess the treatment response . However, the high uptake of 18 F‐fluorodeoxyglucose is not tumor‐specific, which could also be seen in normal tissue or in benign disease‐like inflammation and then lead to false‐positive 18 F‐fluorodeoxyglucose‐PET interpretation …”
Section: Introductionmentioning
confidence: 99%
“…PET with 18 F-fluorodeoxyglucose is a representative imaging technique that can image glucose metabolism of the tumor cells and thus can assess the treatment response. 13,14 However, the high uptake of 18 F-fluorodeoxyglucose is not tumor-specific, which could also be seen in normal tissue or in benign disease-like inflammation and then lead to false-positive 18 F-fluorodeoxyglucose-PET interpretation. 15 Cell death, including apoptosis and necrosis, plays an important role in treatment of cancer.…”
Section: Introductionmentioning
confidence: 99%