2022
DOI: 10.1016/j.isatra.2021.04.010
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Voltage Restorer (DVR) with a novel robust control strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 45 publications
0
5
0
Order By: Relevance
“…The stability analysis (SA) was evaluated using a variety of concepts, involving the Bode diagram, zero pole mapping, and Lyapunov function (LF) [ 57 ]. The LF is taken into account since it was proven to be effective in solving a number of engineering problems [ 58 ].…”
Section: Applied Optimization Methods and Stability Analysismentioning
confidence: 99%
“…The stability analysis (SA) was evaluated using a variety of concepts, involving the Bode diagram, zero pole mapping, and Lyapunov function (LF) [ 57 ]. The LF is taken into account since it was proven to be effective in solving a number of engineering problems [ 58 ].…”
Section: Applied Optimization Methods and Stability Analysismentioning
confidence: 99%
“…Flexible AC transmission system devices like Unified power flow controller (UPFC) [6], Static synchronous series compensators (SSSC) [7], Interline power flow controllers (IPFC) [8], and the Static synchronous compensators (STATCOM) [9], are generally customized to be employed in electrical distribution system known as Custom power devices (CPDs) such as Dynamic Voltage Restorer (DVR) [10], Active filter (AF) [11], Unified power quality conditioner (UPQC) [12], and Distribution static synchronous compensator (DSTATCOM) [13].…”
Section: Introductionmentioning
confidence: 99%
“…The DVR configuration primarily consists of an energy storage unit and a control system. It is connected to the grid via a voltage source inverter, which is linked in series with the grid through an injection electrical device and a low pass filter [10]. DVR control systems are categorized into four main components: detection, reference generation, voltage/current control, and modulation [15].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…DVR is a series connected power electronics switching device and is connected in series with the distribution line to inject the desirable controlled voltage. The DVR includes injection transformer, harmonic filter, voltage source inverter, control unit and DC storage unit [3][4][5][6][7].…”
mentioning
confidence: 99%