2022
DOI: 10.11591/eei.v11i1.3585
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic state power system fault monitoring and protection with phasor measurements and fuzzy based expert system

Abstract: The main aim of this paper is building of a small micro grid test bed system with a few sources, and few loads with various types of lumped resistive (R), capacitive (C) and inductive (L) elements. Before the advent of electric smart grid every load is facilitated with its own electromagnetic. Slowly with an advancement of protection system numerical relays came into existence. Because in the numerical relays the communication between the relays and communication with central computer is possible, with this a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

4
1

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 7 publications
(8 reference statements)
0
4
0
Order By: Relevance
“…Patients who show symptoms of Influenza to verify that they are infected with the Coronavirus, commonly identified as COVID-19 [7]. A study as in [8] aims to build a small microgrid testing system with multiple sources and a few loads with different types of resistive (R), capacitive (C), and inductive (L) elements equalized. There are many process threat factors on the network when exchanging data between devices [9].…”
Section: Introductionmentioning
confidence: 99%
“…Patients who show symptoms of Influenza to verify that they are infected with the Coronavirus, commonly identified as COVID-19 [7]. A study as in [8] aims to build a small microgrid testing system with multiple sources and a few loads with different types of resistive (R), capacitive (C), and inductive (L) elements equalized. There are many process threat factors on the network when exchanging data between devices [9].…”
Section: Introductionmentioning
confidence: 99%
“…Because when the electrical power generation and load demand mismatch then there is a change in the magnitude of the voltage phase angle and frequency. For satisfactory operation of power system all the above variables should monitor properly [3], [4]. For this, phasor measurement unit (PMU) is a perfect device to measure all the above/mentioned parameters [5], [6].…”
Section: Introductionmentioning
confidence: 99%
“…Due to the improper planning and indefinite expansion to meet the demand, the power system network became complex to operate. The present technology supervisory control and data acquisition (SCADA) and express mail service (EMS) which is used for the measurements and monitoring the power system is having the limitations of inaccurate measurements, slower reporting rates which are in the range of once in 4-6 seconds [1], [2] and does not possess common reference time at the measurement stations for the accurate phase comparison between the different stations [3]. The advanced technology phasor measurements with time stamp will overcome the limitations of the SCADA and EMS system [4].…”
Section: Introductionmentioning
confidence: 99%