2012
DOI: 10.1016/j.renene.2011.08.043
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic simulation of thermal energy storage system of Badaling 1 MW solar power tower plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…The receiver is composed of a drum, 7 evaporators and 4 superheater panels. The thermal energy storage system in the demo plant is the combination of a steam accumulator with the volume of 100 m 3 , two heat exchangers, two oil pumps, hot and cold oil storage tanks, where the artificial oil Therminol VP-1, a mixture of biphenyl ether and biphenyl, is used [3].…”
Section: Description Of the Systemmentioning
confidence: 99%
“…The receiver is composed of a drum, 7 evaporators and 4 superheater panels. The thermal energy storage system in the demo plant is the combination of a steam accumulator with the volume of 100 m 3 , two heat exchangers, two oil pumps, hot and cold oil storage tanks, where the artificial oil Therminol VP-1, a mixture of biphenyl ether and biphenyl, is used [3].…”
Section: Description Of the Systemmentioning
confidence: 99%
“…The development of a dynamic simulation tool is important for not only the process design [5], but also to develop operating strategies [6]- [7], investigate normal and off-normal transient behaviours [8], design and testing of process control algorithms [9]- [10], etc. for a solar thermal plant.…”
Section: Cyclic Behavior Of Srsgmentioning
confidence: 99%
“…Till now, most of researches have been devoted to study the dynamic characteristic of the solar thermal power plant. The steam-direct DAHAN tower power plant was modeled by Xu [28,29], of which the dynamic characteristics were discussed. Besides, the dynamic simulation of an indirect thermal storage tank was carried out by Li and Xu [8].…”
Section: Introductionmentioning
confidence: 99%