2012
DOI: 10.1016/j.ijheatmasstransfer.2012.06.094
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic modeling and control of plate heat exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
15
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(16 citation statements)
references
References 12 publications
0
15
0
Order By: Relevance
“…The nonlinear heating substation control system composed of plate heat exchanger, equal percentage valve and PI controller was also established in Simulink with the mathematical models Eq. (5), (6), (10) and (11). The dynamic responses of the heating substation control system were calculated with Simulink.…”
Section: Control and Stability Of Heating Substationmentioning
confidence: 99%
See 1 more Smart Citation
“…The nonlinear heating substation control system composed of plate heat exchanger, equal percentage valve and PI controller was also established in Simulink with the mathematical models Eq. (5), (6), (10) and (11). The dynamic responses of the heating substation control system were calculated with Simulink.…”
Section: Control and Stability Of Heating Substationmentioning
confidence: 99%
“…Al-Dawery [10] established a first order model with time delay to suggest the transient responses of a plate heat exchanger, and a fuzzy logic controller of the plate heat exchanger was designed to achieve less settling time and oscillatory behavior.…”
Section: Introductionmentioning
confidence: 99%
“…The transient dynamics of forced convections for the system can then be analyzed using classical frequency response analysis in control. 11 The heat transfer process is presumably incompressible for the heater and the specimen. The process is described by the heat diffusion equation,…”
Section: B Control-oriented Modelmentioning
confidence: 99%
“…et al [7][8][9][10][11] used high-power laser to generate a rapid temperature rise on the thermocouple surface and obtained the time constant. In addition, there are other methods for dynamic excitation and calibration of thermocouple [12][13][14][15].In the measurement methods and systems for time constant, how to produce stable temperature field and step excitation is the main research content when the system is established. In the above measurement methods, the measurement systems under water flow and air flow environments were constructed for different heat transfer environments.…”
mentioning
confidence: 99%
“…et al [7][8][9][10][11] used high-power laser to generate a rapid temperature rise on the thermocouple surface and obtained the time constant. In addition, there are other methods for dynamic excitation and calibration of thermocouple [12][13][14][15].…”
mentioning