“…Simulations are given to illustrate the load response speed of different ES (Fig.9-14). Since power load control is not the focus of this paper, the control model and method used refers to [22,28]. The control scheme conventional coordinated control system (CCS) refers to the use of fuel flow to adjust pressure before engine, and the use of control valves of HP to adjust the power load [28].…”
Section: Es Used For Increasing Flexibilitymentioning
confidence: 99%
See 1 more Smart Citation
“…Simulations are given to illustrate the load response speed of different ES (Fig.9-14). Since power load control is not the focus of this paper, the control model and method used refers to [22,28]. The control scheme conventional coordinated control system (CCS) refers to the use of fuel flow to adjust pressure before engine, and the use of control valves of HP to adjust the power load [28].…”
Section: Es Used For Increasing Flexibilitymentioning
confidence: 99%
“…Since power load control is not the focus of this paper, the control model and method used refers to [22,28]. The control scheme conventional coordinated control system (CCS) refers to the use of fuel flow to adjust pressure before engine, and the use of control valves of HP to adjust the power load [28]. The control scheme condensate throttling is based on CCS plus a condensate flow adjustment part [28].…”
Section: Es Used For Increasing Flexibilitymentioning
confidence: 99%
“…Similarly, the scheme that utilizing TES capacity in turbine system itself (especially in deaerator and condenser) instead of additional TES facilities has also been proposed, named “condensate throttling” . The specific operational characteristics of the condensate system, control strategy design and dynamic processes simulation, control strategy optimization have been researched in recent years. These works prove that the steam extraction adjustment through condensate throttling can effectively enhance the flexibility of power plants.…”
Section: Introductionmentioning
confidence: 99%
“…Apart from the stored energy of the boiler, a large amount of thermal storage existing in the turbine side has being exploited and utilized in recent years. Lausterer [16] proposed condensate throttling to rapidly increase the power output of thermal power plants and Hu et al [17] set up its nonlinear dynamic model for controller design. Zhao et al [6] and Umezawa [18] developed feed water bypass and high-pressure (HP) extraction throttling techniques to improve the flexibility of unit.…”
Section: Introductionmentioning