Dynamic mechanical relaxation behavior of Zr35Hf17.5Ti5.5Al12.5Co7.5Ni12Cu10 high entropy bulk metallic glass

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(8 citation statements)
references
References 60 publications
(80 reference statements)
0
8
0
Order By: Relevance
“…However, whether these effects still exist in HE-MGs is still under discussion. Recent investigations have reported great advances in the influence of high configurational entropy on the thermodynamics and kinetics of HE-MGs [21][22][23][24] . Benefiting from the sluggish diffusion, the atomic rearrangements of HE-MGs are remarkably hindered 25 .…”
mentioning
confidence: 99%
“…However, whether these effects still exist in HE-MGs is still under discussion. Recent investigations have reported great advances in the influence of high configurational entropy on the thermodynamics and kinetics of HE-MGs [21][22][23][24] . Benefiting from the sluggish diffusion, the atomic rearrangements of HE-MGs are remarkably hindered 25 .…”
mentioning
confidence: 99%
“…Pt 20 Cu 20 Ni 20 P 20 HE-BMG exhibits a "shoulder"[53]. In this study, La 30 Ce 30 Ni 10 Al 20 Co 10 HE-BMG shows a conspicuous β relaxation peak for establishing the correlation between relaxation dynamics and creep mechanism.…”
mentioning
confidence: 50%
“…Figure 2 (Color online) (a) Dependence of the normalized storage modulus E′/E u and loss modulus E″/E u of the La 30 Ce 30 Ni 10 Al 20 Co 10 HE-BMG on temperature obtained at a driving frequency of 0.5 Hz and a heating rate of 3 K/min. Here, E u is the storage modulus at room temperature; (b) the normalized loss modulus E″/E″ max in La 30 Ce 30 Ni 10 Al 20 -Co 10 , Pd 20 Pt 20 Cu 20 Ni 20 P 20 , and Zr 35 Hf 17.5 Ti 5.5 Al 12.5 Co 7.5 Ni 12 Cu 10 HE-BMGs as a function of the normalized temperature T/T α[53]. E″ max is the maximum of the loss modulus, and T α is the temperature of the peak of the main α relaxation.…”
mentioning
confidence: 99%
“…In the temperature range of 600 K-730 K, the loss and storage moduli show the sharp increasing and decreasing trends, respectively. is event is associated to the β and α relaxations, occurring under the glass transition temperature [29,30]. Finally, the contradictory behavior of moduli above 770 K is correlated to the nucleation and growth of crystals in the microstructure [25].…”
Section: Resultsmentioning