Dynamic heat transfer analysis of liquefied natural gas ambient air vaporizer under frost conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(10 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…temperature, relative humidity and velocity [39]. Among these, surface temperature is the main influence factor [40], which is also demonstrated in the results of the model in examination. The system model considering extra frost layers may reveal the degree of performance degradation after certain time.…”
Section: Frosting Influencementioning
confidence: 63%
See 1 more Smart Citation
“…temperature, relative humidity and velocity [39]. Among these, surface temperature is the main influence factor [40], which is also demonstrated in the results of the model in examination. The system model considering extra frost layers may reveal the degree of performance degradation after certain time.…”
Section: Frosting Influencementioning
confidence: 63%
“…The frost formation on the surface restricts the operation of the heat exchanger, thus several methods are employed to defrost such as switch operation time. A second identical heat exchanger unit is made available to allow the primary unit to defrost for minimum 4 hours [40]. Another method is to change the surface structure.…”
Section: Frosting Influencementioning
confidence: 99%
“…where C0 is the black body radiation coefficient which value is 5.67 W/(m 2 •K 4 ), ɛ1 is the emissivity of the inner plate which value is 0.8; T1 is the inner wall temperature of the solar wall (K), A0 is the surface area of the AAV (m 2 ), a, b, c is the length, width and height of the AAV, respectively (m), A1 is the surface area of inner wall (m 2 ), l is the height of the solar wall (m) and hs is the composite convective heat transfer coefficient of air jet flow (W/(m 2…”
Section: Heat Transfer Coefficient Of Avcswmentioning
confidence: 99%
“…Unfortunately, ice and frost phenomenon will naturally emerge during the operation of AAV, which worsens its thermal performance. Jiao simulated the formation of frost layer and studied the boiling heat transfer in the pipe of L N G with CFD [2]. Handy Afrianto concluded that the optimization of mass flow was favorable for the vaporization of L N G [3].…”
Section: Introductionmentioning
confidence: 99%
“…The selected relations of the above parameters were proposed for optimal design of vaporizers. The coupled dynamic model of frost formation and flow boiling heat transfer of LNG was presented in paper [5]. One of the main conclusions of the above study was that the thermal resistance of the frost layer increased with the operation time and is the major factor affecting the temperature of finned tube walls.…”
Section: Introductionmentioning