2022
DOI: 10.1016/j.mycmed.2022.101303
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic full-field optical coherence tomography as complementary tool in fungal diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…As previously described ( Ghouali et al., 2015 ; Maldiney et al., 2020 ; Maldiney et al., 2022 ), D-FF-OCT images were acquired at room temperature with the Light-CT Scanner apparatus accessible at Langevin Institute (LLTech – Aquyre Biosciences). As described in Supplementary Figure S1 and Supplementary Table , the system associates a conventional halogen light source with short temporal coherence length and a set of 10× water immersion microscope objectives with a numerical aperture of 0.3 in a so-called Linnik configuration to reach a final axial and transverse resolution of approximately 1–1.5 µm.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…As previously described ( Ghouali et al., 2015 ; Maldiney et al., 2020 ; Maldiney et al., 2022 ), D-FF-OCT images were acquired at room temperature with the Light-CT Scanner apparatus accessible at Langevin Institute (LLTech – Aquyre Biosciences). As described in Supplementary Figure S1 and Supplementary Table , the system associates a conventional halogen light source with short temporal coherence length and a set of 10× water immersion microscope objectives with a numerical aperture of 0.3 in a so-called Linnik configuration to reach a final axial and transverse resolution of approximately 1–1.5 µm.…”
Section: Methodsmentioning
confidence: 99%
“…A contrast-based ImageJ protocol called the “Plot Profile” function allowed length measurements of each fungal compartment for both standard and dynamic contrast images. Finally, as stated in our previous study regarding the specific analysis of D-FF-OCT images ( Maldiney et al., 2022 ), a fast Fourier transform program was used to study the time series corresponding to each pixel behavior. The power spectrum density was split into three parts of equal energy, each matching one of the three main colors of the composite RGB image.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 2b compares OCT, DyC-OCT, and histology images of benign breast lobules and invasive breast tissue, where DyC-OCT dramatically enhances the contrast of OCT, and reports a high diagnostic accuracy 40 . DyC-OCT has also demonstrated the potential of fungal infection diagnosis to visualize 3D structures of Nannizzia gypsea, Aspergillus fumigatus, and Rhizopus arrhizus 41 . Overall, DyC-OCT can benefit disease diagnosis by enhancing cellular dynamic contrast to reveal changes in morphological features.…”
Section: Applications Of Dyc-octmentioning
confidence: 99%