2019
DOI: 10.1007/978-1-4939-9187-7_7
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Force Spectroscopy Analysis on the Redox States of Protein Disulphide Bonds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 29 publications
0
12
0
Order By: Relevance
“…2 a, top). After RBCs were injected into the chamber, a fashioned borosilicate micropipette was anchored on the micropipette holder and inserted into the chamber by tuning the micro-manipulator as previously described (Chen et al 2015 ; Ju 2019 ). The micropipette was then approached to grab the target RBC (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…2 a, top). After RBCs were injected into the chamber, a fashioned borosilicate micropipette was anchored on the micropipette holder and inserted into the chamber by tuning the micro-manipulator as previously described (Chen et al 2015 ; Ju 2019 ). The micropipette was then approached to grab the target RBC (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Tips of micropipettes were cut and fashioned to 1 µm diameters using a MicroForge (Model MF-900; Narishige International, USA) equipped with a 20 × eyepiece. For detailed operation procedures, please refer to the previously published protocols (Ju 2019 ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Towards a further understanding of the structure–function relationship with respect to the N-AIM of VWF-A1, we employed the DFS technique—BFP to characterize the VWF-A1–GPIbα interaction in a bead–bead mode as previously established. 58 VWF-A1 was coated on a glass bead (probe) attached to the apex of a micropipette-aspirated red blood cell (RBC) ( Fig. 2a and b , left), and GPIbα was immobilized on another glass bead (Target) aspirated using an apposing micropipette ( Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Figure 1D demonstrates various applications of bio-AFM (Hoh and Hansma 1992;Shao and Yang 1995;Czajkowsky et al, 2000;Hansma 2001;Goldsbury and Scheuring 2002;Malkin et al, 2002;Alonso and Goldmann 2003;Besch et al, 2003;Gadegaard 2006;Shahin and Barrera 2008;Goldsbury et al, 2009;Ramachandran et al, 2011;Kreplak 2016;Dufrene et al, 2017;Braet and Taatjes 2018;Gao et al, 2018;Cheong et al, 2019;Nandi and Ainavarapu 2021), and we are about to summarize these in this review. Unlike the AFM imaging modes where the probe is scanned over the surface of the substrate, the cantilever tip is first approached toward the substrate until tip-sample contact happens and then retracted in AFM dynamic force spectroscopy (AFM-DFS) (Sulchek et al, 2005;Neuert et al, 2006;Thormann et al, 2006;Diezemann and Janshoff 2008;Alessandrini et al, 2012;Sengupta et al, 2014;Sluysmans et al, 2018;Ju 2019;Reiter-Scherer et al, 2019;Alhalhooly et al, 2021) and single-molecule force spectroscopy (AFM-SMFS) experiments. These two are similar methods with slight differences.…”
Section: Introductionmentioning
confidence: 99%