Chest Wall Deformities 2017
DOI: 10.1007/978-3-662-53088-7_46
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Compressor System for Pectus Carinatum Repair

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…24 They developed a pressure-measuring device, which enables the surgeon to measure the pressure of initial correction (PIC) to correct PC as well as the pressure of treatment (POT) which may be used during application of the DCS. [24][25][26] The DCS with the pressure-measuring device permits pressure measurement during therapy (POT), prediction of treatment duration and prognosis, and in-situ outpatient clinic adjustments and avoids patient manipulation. 25,26 In the meantime, numerous studies and authors could confirm the effectiveness of the DCS.…”
Section: Treatment Of Pectus Carinatummentioning
confidence: 99%
See 1 more Smart Citation
“…24 They developed a pressure-measuring device, which enables the surgeon to measure the pressure of initial correction (PIC) to correct PC as well as the pressure of treatment (POT) which may be used during application of the DCS. [24][25][26] The DCS with the pressure-measuring device permits pressure measurement during therapy (POT), prediction of treatment duration and prognosis, and in-situ outpatient clinic adjustments and avoids patient manipulation. 25,26 In the meantime, numerous studies and authors could confirm the effectiveness of the DCS.…”
Section: Treatment Of Pectus Carinatummentioning
confidence: 99%
“…[24][25][26] The DCS with the pressure-measuring device permits pressure measurement during therapy (POT), prediction of treatment duration and prognosis, and in-situ outpatient clinic adjustments and avoids patient manipulation. 25,26 In the meantime, numerous studies and authors could confirm the effectiveness of the DCS. [27][28][29][30][31][32] Summarizing the experiences of different authors, patients under the age of 14 to 15 years with symmetric PC and high motivation toward correction represent the best candidates for this treatment method.…”
Section: Treatment Of Pectus Carinatummentioning
confidence: 99%
“…Bracing has become a more common treatment for the individuals with PC [3,4,23]. The brace used in this study, the FMF Dynamic Compressor System, is adjustable and is fitted to each patient; made from curved aluminum segments, shoulder straps, cushioned compression plates, and pads to cushion the defect as shown in Fig 1 . An instrumented measuring pad is also used to assist in fitting [27,28].…”
Section: Introductionmentioning
confidence: 99%