Duty Cycle-Based Differential Protection Scheme for Power Transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…Considering the fact that it is difficult and costly to determine an accurate threshold limit for protection algorithms in all different operating conditions and that an inaccurate threshold may result in the incorrect blocking of the DP or a delay in its operation, dependence on the threshold limit can be considered one of the main disadvantages of the protection methods presented in [8] and [7]. The authors in [4], [5], and [7] have not studied the accuracy of their methods in noise conditions. Nevertheless, the presence of noise may have a considerable effect on the accuracy and efficiency of those methods.…”
Section: Comparison With Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering the fact that it is difficult and costly to determine an accurate threshold limit for protection algorithms in all different operating conditions and that an inaccurate threshold may result in the incorrect blocking of the DP or a delay in its operation, dependence on the threshold limit can be considered one of the main disadvantages of the protection methods presented in [8] and [7]. The authors in [4], [5], and [7] have not studied the accuracy of their methods in noise conditions. Nevertheless, the presence of noise may have a considerable effect on the accuracy and efficiency of those methods.…”
Section: Comparison With Related Workmentioning
confidence: 99%
“…Using threshold values to separate IFs from IC is one of the main disadvantages of the DP method. In [7], the security concerns associated with DP for power transformers are outlined. To overcome these issues, three protective criteria are proposed using the duty cycle concept.…”
Section: Introductionmentioning
confidence: 99%
“…The relay may operate during through fault due to spill current since the I di f f pickup was the only setting of the differential relay, which is highly undesirable. To mitigate this issue, restraining or biasing is provided based on the loading condition of the protected object through restraining coils, and their setting results in percentage bias characteristics (slope characteristics) of the relay, which essentially results in restraining the operation of the relay [13]. The restraint (biasing) characteristics provide stability to the differential relay during normal and through fault scenarios; therefore, the differential relays are called percentage biased differential relays.…”
Section: Differential Relaymentioning
confidence: 99%
“…Power transmission and distribution technology can reduce energy loss and environmental pollution in the power system, thus playing a positive role in solving energy crisis and environmental problems. Protection and control technology is a very important part of the PET system, including modulation and soft switching technology, control technology and fault protection technology [1,2].…”
Section: Introductionmentioning
confidence: 99%