Volume 1: Plant Operations, Maintenance, Engineering, Modifications, Life Cycle, and Balance of Plant; Component Reliability An 2012
DOI: 10.1115/icone20-power2012-54493
|View full text |Cite
|
Sign up to set email alerts
|

Dust Generation and Transport Behavior in the Primary Circuit of HTTR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…Further, carbon dust of the piston rings has been circulated in the primary cooling system. This carbon dust increased differential pressures in the filters of primary helium gas circulators [6]. Due to the increase in differential pressures in filters, the filters on primary helium gas circulators had to be replaced twice [7].…”
Section: Abnormal Abrasion Of Piston Ringsmentioning
confidence: 99%
“…Further, carbon dust of the piston rings has been circulated in the primary cooling system. This carbon dust increased differential pressures in the filters of primary helium gas circulators [6]. Due to the increase in differential pressures in filters, the filters on primary helium gas circulators had to be replaced twice [7].…”
Section: Abnormal Abrasion Of Piston Ringsmentioning
confidence: 99%