2021
DOI: 10.1016/j.athoracsur.2020.07.040
|View full text |Cite
|
Sign up to set email alerts
|

Durability and Performance of 2298 Trifecta Aortic Valve Prostheses: A Propensity-Matched Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
46
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(53 citation statements)
references
References 20 publications
7
46
0
Order By: Relevance
“…Our findings are in line with those from the Finn-Valve study, where at 7 years the all-cause mortality was reported to be 32% in patients with Trifecta vs. 23% in patients with Perimount ( p = 0.755). To our knowledge, to date, there is only one comparative study between these prostheses, with very similar findings as ours ( 12 ). Yongue et al ( 12 ) compared recently the durability and hemodynamic performance of 2,298 Trifecta prostheses with 1:1 propensity matched Perimount prostheses.…”
Section: Discussionsupporting
confidence: 85%
See 1 more Smart Citation
“…Our findings are in line with those from the Finn-Valve study, where at 7 years the all-cause mortality was reported to be 32% in patients with Trifecta vs. 23% in patients with Perimount ( p = 0.755). To our knowledge, to date, there is only one comparative study between these prostheses, with very similar findings as ours ( 12 ). Yongue et al ( 12 ) compared recently the durability and hemodynamic performance of 2,298 Trifecta prostheses with 1:1 propensity matched Perimount prostheses.…”
Section: Discussionsupporting
confidence: 85%
“…Yongue et al ( 12 ) compared recently the durability and hemodynamic performance of 2,298 Trifecta prostheses with 1:1 propensity matched Perimount prostheses. In their study Trifecta bioprosthesis exhibited superior early hemodynamic performance, but had a rapid increase in transvalvular gradient and more aortic regurgitation, with lower freedom from explant at 5 years, which raises concern regarding long-term Trifecta durability despite favorable early hemodynamics ( 12 ).…”
Section: Discussionmentioning
confidence: 99%
“…24,25 Likewise, a recent comparative analysis of the Perimount (internally mounted) bioprosthesis and the Trifecta (externally wrapped) valve highlighted that despite the latter exhibited superior early haemodynamic performance, its durability was compromised by a rapid increase in transvalvular gradient and more aortic regurgitation, resulting in lower freedom from explant at 5 years. 26 Further longitudinal studies will be mandatory to elucidate the relationship (either beneficial or negative) of the opening reserve on the wear and tear stresses on the leaflets, the risk of SVD, and ultimately the durability of the Avalus valve.…”
Section: Discussionmentioning
confidence: 99%
“…Among the 30 patients, 27 were men (90%), and the mean age was 69.5 (65.0-74.2) years. At rest, the prevalence of moderate and severe measured PPM was 40% (12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30) and 20% (6-30), respectively. No significant difference was seen regarding body surface area (BSA), body mass index (BMI), blood pressure, and comorbidities among the three PPM subgroups.…”
Section: Baseline Clinical Characteristics Of the Study Populationmentioning
confidence: 99%
“…Several comparative studies suggest a higher incidence of structural valve degeneration (SVD) with Trifecta valves compared to other stented bioprotheses 6,7 . These studies are single‐center midterm analyses and represent concerning trends that warrant further investigation 7,8 . The lack of prospective or randomized trial data limits the inferences that can be confidently made and additional data can help clarify the strength of the finding and generalizability to other centers.…”
Section: Introductionmentioning
confidence: 99%