The dome stretching tests and tension tests have been performed to obtain a forming limit curve(FLC) for the copper alloy which is used for manufacturing the regenerative cooling thrust chamber. For experimental investigation of the forming limit curve, we have used in-plane tension specimen to obtain tension-compression strain state as well as out-of-plane specimen to obtain tension-tension strain state through dome stretching test. All specimens were divided into longitudinal and transverse directions according to the orientation of test specimen. The test results showed that in the tension-tension region, copper alloy revealed a maximum major strain of 62.3% and a maximum minor strain of 58.6%. In the tension-compression region, the maximum major strain and the maximum minor strain were measured to be 60.5% and 25.8%, respectively.