Dual-Source Dual-Energy CT in Submandibular Sialolithiasis: Reliability and Radiation Burden

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…Next to diagnostic benefits, DECT offers the chance of significant dose reduction, in particular by abolishing the obligation of a complete unenhanced scan due to reconstruction of virtual unenhanced images 3 7 . Nevertheless, comparative risk assessment of SECT and DECT should not only focus on radiation dose and dose rate, but also has to consider differences in biological effectiveness (BE) associated with varying photon energies 8 10 .…”
Section: Introductionmentioning
confidence: 99%
“…Next to diagnostic benefits, DECT offers the chance of significant dose reduction, in particular by abolishing the obligation of a complete unenhanced scan due to reconstruction of virtual unenhanced images 3 7 . Nevertheless, comparative risk assessment of SECT and DECT should not only focus on radiation dose and dose rate, but also has to consider differences in biological effectiveness (BE) associated with varying photon energies 8 10 .…”
Section: Introductionmentioning
confidence: 99%
“…Its boundary can be identified more accurately, which is beneficial to multi-parameter measurement and diagnosis of small lymph nodes with dual-energy CT. Small FOV, thinsection, and multi-planar reconstruction can help observe cervical LNs from different planes, detect more small LNs and discover more features in one LN, which help to diagnose metastatic LN (8). CARE Dose 4D or iterative reconstruction algorithm can reduce the radiation dose so that the radiation dose of CT at small FOV is not higher than that of CT at conventional FOV; dual-source dual-energy CT with energy spectrum purification technique reduces the radiation dose (10,11), leading to a 30% radiation dose reduction.…”
Section: Discussionmentioning
confidence: 99%
“…After using small FOV, the improved resolution is helpful to display internal features in these small lymph nodes. CARE Dose 4D or iterative reconstruction algorithm can reduce the radiation dose so that the radiation dose of CT at small FOV is not higher than that of CT at conventional FOV; dual-source dual-energy CT with energy spectrum puri cation technique, reduces the radiation dose [5,6] , leading to a 30% radiation dose reduction. Macrometastatic LNs must be treated, because it leads to worse prognosis.…”
Section: Discussionmentioning
confidence: 99%