2017
DOI: 10.1007/s00604-017-2471-1
|View full text |Cite
|
Sign up to set email alerts
|

Dual signal amplification strategy for amperometric aptasensing using hydroxyapatite nanoparticles. Application to the sensitive detection of the cancer biomarker platelet-derived growth factor BB

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 35 publications
(5 citation statements)
references
References 43 publications
0
5
0
Order By: Relevance
“…On the other hand, the electrode with modified AuNPs shows two pairs of robust current peaks (Figure , curve c). This strong electrochemical current is due to the reaction of the dC 20 DNA on the AuNP surface, specifically the reaction of the phosphate backbone of dC 20 with molybdate to form the redox-active molybdophosphate precipitate as shown in our previous reports. This previous work probed in detail the reaction of DNA strands composed of different nucleotide bases with molybdate, leading to the possibility that the polycytosine sequence generates the highest current intensity . As in the description above, electron transfer within the molybdophosphate leads to two pairs of redox peaks (0.22 and 0.35 V).…”
Section: Resultsmentioning
confidence: 65%
“…On the other hand, the electrode with modified AuNPs shows two pairs of robust current peaks (Figure , curve c). This strong electrochemical current is due to the reaction of the dC 20 DNA on the AuNP surface, specifically the reaction of the phosphate backbone of dC 20 with molybdate to form the redox-active molybdophosphate precipitate as shown in our previous reports. This previous work probed in detail the reaction of DNA strands composed of different nucleotide bases with molybdate, leading to the possibility that the polycytosine sequence generates the highest current intensity . As in the description above, electron transfer within the molybdophosphate leads to two pairs of redox peaks (0.22 and 0.35 V).…”
Section: Resultsmentioning
confidence: 65%
“…In actual sample, 100–1000 times the interfering substances are seen, but most of the interference experiments have reported so far the target and interference at a concentration ratio of 1 : 10. 50–52 Therefore, we have selected GPC3 with a concentration of 10.0 μg mL −1 and interfering protein with a concentration of 100.0 μg mL −1 for measurement and compared the DPV peak current signals, and the results are shown in Fig. 6A.…”
Section: Resultsmentioning
confidence: 99%
“…As also reported in our recent review (Arduini et al, 2017), many electrochemical (bio)sensors have been developed for biomedical applications (Huang X. et al, 2017;Jiang et al, 2017). This manuscript was inspired by the unequal use of sensors in the pharmaceutical sector, where optical devices are abundant while the electrochemical ones are still in their infancy, despite their potential has been already demonstrated.…”
Section: Introductionmentioning
confidence: 88%