2020
DOI: 10.1109/tbme.2019.2936088
|View full text |Cite
|
Sign up to set email alerts
|

Dual Scan Mammoscope (DSM)—A New Portable Photoacoustic Breast Imaging System With Scanning in Craniocaudal Plane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
33
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 48 publications
(34 citation statements)
references
References 40 publications
1
33
0
Order By: Relevance
“…Current results indicate that using multiple light illumination angles, along with optimizing imaging geometry can improve light penetration. 34,51 In addition to that, engineering PA-based contrast agents could be another solution to facilitate deep tissue imaging. [85][86][87] Second, although multispectral PA imaging enables the functional quantification of breast tissue, the complexity of light absorption and scattering in tissue make the quantification inaccurate.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Current results indicate that using multiple light illumination angles, along with optimizing imaging geometry can improve light penetration. 34,51 In addition to that, engineering PA-based contrast agents could be another solution to facilitate deep tissue imaging. [85][86][87] Second, although multispectral PA imaging enables the functional quantification of breast tissue, the complexity of light absorption and scattering in tissue make the quantification inaccurate.…”
Section: Discussionmentioning
confidence: 99%
“…31,32 The planar detection is implemented using a small planar array 33 or by scanning the object with a linear array. 34 Apart from classification based on imaging geometry, the systems can also be categorized based on the scanning mechanism, i.e., handheld imaging systems and tomographic imaging systems. In handheld systems, the imaging probe can be used similar to a clinical breast US, whereas in tomographic imaging systems, the US probe is connected to a motorized stage for automated scanning.…”
Section: Imaging Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…Compared to the 2D array probe, it is much easier to manufacture a linear array with smaller element size, as well as its parallel data acquisition system. Nikhila et al [22] presented a dual scan mammoscope system by two focused array, and they employed the "virtual line" algorithm to successfully improve the elevation resolution. But the inherent focusing characteristic of this probe still limits its effective acquisition angle, making it difficult to image vertically obliquely aligned targets in 3D.…”
Section: Introductionmentioning
confidence: 99%