2021
DOI: 10.1016/j.jpowsour.2021.230234
|View full text |Cite
|
Sign up to set email alerts
|

Dual-porous structured membrane for ion-selection in vanadium flow battery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 47 publications
0
6
0
Order By: Relevance
“…6i). 15,[20][21][22][42][43][44] Besides, the selfdischarge time of the battery with the NP-Fiber membrane reaches 150 h, which is strikingly higher than that with the N212 membrane (60 h) in Fig. 6h, further demonstrating the high ion selectivity of the optimized NP-Fiber-3 membrane.…”
Section: Optimizationmentioning
confidence: 89%
“…6i). 15,[20][21][22][42][43][44] Besides, the selfdischarge time of the battery with the NP-Fiber membrane reaches 150 h, which is strikingly higher than that with the N212 membrane (60 h) in Fig. 6h, further demonstrating the high ion selectivity of the optimized NP-Fiber-3 membrane.…”
Section: Optimizationmentioning
confidence: 89%
“…By removing template agents (or pore-forming agents) to create pores, ICMs with relatively regular pore structures and well-controlled pore size can be obtained (Figure e). ,,, The applied templates include solvent, polyethylene glycol (PEG), β-cyclodextrin (β-CD), phenolphthalein, SiO 2 , etc. Compared with phase inversed methods, ICMs fabricated by template methods have more uniform pore structures by adjusting the content and distributions of template agents (Figure e and e).…”
Section: Icms For Vfbsmentioning
confidence: 99%
“…Furthermore, the pore size of fabricated ICMs is somehow relatively larger, causing low selectivity (Figure e). For instance, the vanadium permeability of a ICM fabricated by a template method was 2.39 × 10 –4 cm 2 h –1 (area resistance: 4.74 Ω cm 2 ). ,,, As a result, using template methods to optimize the membrane performance is not widely studied nowadays.…”
Section: Icms For Vfbsmentioning
confidence: 99%
See 1 more Smart Citation
“… ( a ) Comparison of cycle efficiencies of the three membranes at 200 mA cm −2 ; ( b ) discharge capacity retention of the pure PFSA, PE/PFSA composite, and Nafion212 membranes; and ( c ) EE comparison between PE/PFSA and other existing advanced membranes at different current densities [ 7 , 26 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 ]. …”
Section: Figurementioning
confidence: 99%