Dual energy iodine contrast imaging with mammography and tomosynthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
2
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…Moreover, the radiation dose was estimated to be only 1.2 times that of a regular mammogram [30]. The radiation dose for CEDM (sum of high- and low-energy image dose) for a woman with average breast size (equivalent to 4.2-cm compressed breast thickness with 50% fat and 50% glandular composition) is <3.0 mGy [12]. Finally, CEDM provides an easy and simple method for the surgeon and clinician to interpret images without having to know the many complicated parameters of CEMRI.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the radiation dose was estimated to be only 1.2 times that of a regular mammogram [30]. The radiation dose for CEDM (sum of high- and low-energy image dose) for a woman with average breast size (equivalent to 4.2-cm compressed breast thickness with 50% fat and 50% glandular composition) is <3.0 mGy [12]. Finally, CEDM provides an easy and simple method for the surgeon and clinician to interpret images without having to know the many complicated parameters of CEMRI.…”
Section: Discussionmentioning
confidence: 99%
“…Four routine views were acquired within 5 minutes, starting at 2 minutes after the injection (Figure 1). The mean radiation dose per view was 1.2 mGy for digital mammography and <3.0 mGy for CEDM (4.2 cm compressed breast thickness) [12]. The target breast was defined as the side containing the proven malignancy, and the nontarget breast as the opposite side of the proven malignancy.…”
Section: Methodsmentioning
confidence: 99%
“…All CEDM examinations were performed within 7 days of CEMRI using a digital mammography device capable of dual energy CEDM acquisition (Selenia Dimensions; Hologic, Bedford, USA). Previously, techniques of CEDM and CEMRI were described in detail [9,10].…”
Section: Contrast-enhanced Digital Mammography and Contrastenhanced Mmentioning
confidence: 99%
“…26,27 Great effort has been devoted to the development and optimization of CEDBT. 10,[28][29][30][31][32][33][34][35][36] The feasibility of CEDBT has also been demonstrated in a pilot clinical study using a photon-counting DBT system to allow spectral imaging in single shot with low dose. 37 It has been shown that DBT provides more accurate tumor margin assessment and size measurement than FFDM.…”
Section: Introductionmentioning
confidence: 99%