2019
DOI: 10.1016/j.snb.2019.126775
|View full text |Cite
|
Sign up to set email alerts
|

Dual-colored carbon dot encapsulated metal-organic framework for ratiometric detection of glutathione

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
52
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 118 publications
(52 citation statements)
references
References 52 publications
0
52
0
Order By: Relevance
“…High concentration of GSSG causes diseases such as asthma, human immunodeficiency virus type 1 infection, and chronicle renal failure [12] . Therefore, determining the GSH, [13] GSSG [14] or GSH/GSSG ratio [15] is an important biomarker.…”
Section: Introductionmentioning
confidence: 99%
“…High concentration of GSSG causes diseases such as asthma, human immunodeficiency virus type 1 infection, and chronicle renal failure [12] . Therefore, determining the GSH, [13] GSSG [14] or GSH/GSSG ratio [15] is an important biomarker.…”
Section: Introductionmentioning
confidence: 99%
“…A ratiometric luminescent sensor for selectively detecting GSH was prepared by the encapsulating of blue-emitting CDs (BCDs) and yellow emitting CDs (YCDs) into the zeolitic imidazolate framework (B/YCDs@ZIF-8). [246] The luminescence of BCDs of the B/YCDs@ZIF-8 was quenched while the luminescence of the YCDs was enhanced upon immersion of the B/YCDs@ ZIF-8 composite in a Cu 2+ solution, which was attributed to the coordination of Cu 2+ ions with COOH groups/NH 2 group on the surface of BCDs/YCDs. After adding GSH to the Cu 2+ -BYCDs@ZIF-8 system, the fluorescence intensity of both CDs could be well recovered due to the strong interaction between GSH and Cu 2+ .…”
Section: Biomolecular Sensingmentioning
confidence: 96%
“…[140] Furthermore, yellow-emitting and blue-emitting CDs were encapsulated in ZIF-8 to prepare a dual-emission composite BYCDs@ZIF-8. [150] Nevertheless, the inherent large size of CDs requires MOFs with a large aperture for effective encapsulation, which limits the selection range of MOF hosts.…”
Section: Perovskitesmentioning
confidence: 99%
“…Among these techniques, electrochemical methods are widely used for the determination of many molecules since they have advantages like being economical, simple, and accurate. [29][30][31][32] Various modifiers such as silica nanoparticles, [33] carbon dots [34] and βcyclodextrin, [35,36] have been utilized for GSH detection in order to lower the mandatory over potential for GSH oxidation. [37] Also different electroanalytical techniques like amperometric, [38,39] advanced voltammetric techniques like square-wave voltammetry, [40] differential pulse voltammetry (DPV), [41] cyclic voltammetry [42] stripping voltammetry [43] and hydrodynamic voltammetry [44] were tested for the increment of efficacy of electrochemical detection methods for GSH.…”
Section: Introductionmentioning
confidence: 99%