2021 IEEE PES/IAS PowerAfrica 2021
DOI: 10.1109/powerafrica52236.2021.9543214
|View full text |Cite
|
Sign up to set email alerts
|

DSTATCOM Application for Distribution Network Power Quality Enhancement: A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…1. Mainly, the components of D-STATCOM include the following parts: voltage converter, DC energy unit storage, transforming the injection, and finally the controlling unit [10]. D-STATCOM output AC voltage side (Vc) is adjusting to the desired voltage.…”
Section: Distribution Static Compensatormentioning
confidence: 99%
See 1 more Smart Citation
“…1. Mainly, the components of D-STATCOM include the following parts: voltage converter, DC energy unit storage, transforming the injection, and finally the controlling unit [10]. D-STATCOM output AC voltage side (Vc) is adjusting to the desired voltage.…”
Section: Distribution Static Compensatormentioning
confidence: 99%
“…1. D-STATCOM schematic diagram[10] D-STATCOM output AC voltage side (Vc) is adjusting to the desired voltage. D-STATCOM absorbs reactive power if the system voltage (Vs) magnitude at PCC is higher than the desired voltage; while if the voltage magnitude at PCC is smaller than the desired voltage, reactive power is injected into the system to increase its voltage; and if the system voltage is equal to the desired voltage, the D-STATCOM is not injecting or absorbing any reactive power[11].…”
mentioning
confidence: 99%
“…Solar and wind energy are the leading RESs according to the amount of energy installed but are not problem-free. For example, if these energy sources are disconnected during severe contingencies or disturbances, there could be serious challenges to the supply of reactive power, leading to difficulties in maintaining bus voltages within acceptable ranges [3] and constraints to power transfer [4], which can lead to voltage instability [5]. These RESs are interfaced into the system using converters, which have a non-linear behaviour [6][7][8] and are sources of harmonics.…”
Section: Introductionmentioning
confidence: 99%
“…The decline of voltages at load terminals are among the most popular power quality issues today [8]. A voltage drop happens whenever the operating voltage falls below its real rating due to the load's excessive reactive power consumption [9].…”
Section: ░ 1 Introductionmentioning
confidence: 99%