2006 IEEE/PES Transmission &Amp; Distribution Conference and Exposition: Latin America 2006
DOI: 10.1109/tdcla.2006.311376
|View full text |Cite
|
Sign up to set email alerts
|

DSP-based Direct Power Control of a VSC with Voltage Angle Estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…In this algorithm, presented in [23], a new table is proposed based on geometrical considerations. This table is simpler than Noguchi's (6 sectors instead of 12) and yields better results.…”
Section: E Results For Eloy-garcía's Tablementioning
confidence: 99%
See 2 more Smart Citations
“…In this algorithm, presented in [23], a new table is proposed based on geometrical considerations. This table is simpler than Noguchi's (6 sectors instead of 12) and yields better results.…”
Section: E Results For Eloy-garcía's Tablementioning
confidence: 99%
“…Since the original table was published in [6], several alternative switching tables have been proposed [6], [23] trying to improve the behavior of the system. Yet, they all share some common shortcomings due to some assumptions made in the algorithm.…”
Section: Analysis Of Conventional Dpc-tmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the execution Numerous PWM strategies have been proposed to solve the neutral-point voltage unbalance problem. Many of these techniques still use the complicated dwelling time calculation and the switching sequence selection method [12], [14], [16]. The neutral-point voltage control algorithm is easily implemented, and the dwelling time calculation and the switching sequence selection are easily conducted similar to that of a conventional two-level rectifier when the new PWM strategy is used.…”
Section: Neutral-point Voltage Balance Strategy Based On Simplifiementioning
confidence: 99%
“…The PI controllers experience lag in the sinusoid response for certain frequencies [13]. The direct power based on the SVM control has to track the phase angle of the grid voltage and transform to a synchronous rotating coordinate reference frame [14], [15]. The sliding mode control methodology is an effective, high-frequency switching control for non-linear systems with uncertainties.…”
Section: Introductionmentioning
confidence: 99%