1978
DOI: 10.1515/cclm.1978.16.2.103
|View full text |Cite
|
Sign up to set email alerts
|

Drug Interference in Clinical Chemistry: Studies on Ascorbic Acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0
4

Year Published

1980
1980
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 10 publications
0
8
0
4
Order By: Relevance
“…A variação pré-analítica é o erro de resultado da sumarização de todos os limites de variação, desde a coleta da amostra, transporte e preservação antes da introdução do sistema analítico. Este é especialmente importante, podendo levar a variações instrumentais, que são erros durante o método de análise, podendo estes, serem controlados e documentados (SIEST et al, 1988).…”
Section: Interferências Analíticasunclassified
See 2 more Smart Citations
“…A variação pré-analítica é o erro de resultado da sumarização de todos os limites de variação, desde a coleta da amostra, transporte e preservação antes da introdução do sistema analítico. Este é especialmente importante, podendo levar a variações instrumentais, que são erros durante o método de análise, podendo estes, serem controlados e documentados (SIEST et al, 1988).…”
Section: Interferências Analíticasunclassified
“…Também são inclusos os fatores genéticos como a raça, além dos fatores externos, como o tabagismo, nutrição e condições sociais (SIEST et al, 1988).…”
Section: Interferências Analíticasunclassified
See 1 more Smart Citation
“…In 1978 an expert group was convened within the European Community to study drug interferences and establish recommendations. 1 In 1984 the French Society of Clinical Chemistry and the International Federation of Clinical Chemistry also addressed this issue and published, in French and in English, recommendations for the evaluation of drug interferences. 2,3 The National Committee for Laboratory Standards published proposed guidelines for interference testing in 1986.…”
Section: Introductionmentioning
confidence: 99%
“…Their blood glucose levels were determined 8-12 h after the last vitamin C intake using three 'specific' enzymatic assays: glucose dehydrogenase [5), hexokinase [6] and glucose oxidase [7]. In normal subjects, blood glucose determinations using hexokinase and glucose oxidase, respectively, yield identical results when inter fering substances are excluded [2,8,9], The oxidizable substance, vitamin C, interferes with the latter enzymatic reaction during the second step of the determination process [1], No such interference is noted with the glucose dehydrogenase and the hexokinase assay systems, which are direct measurement methods. The results of the present study arc shown in table I.…”
mentioning
confidence: 99%