Every anatomical lung resection requires the airtight closure of at least one bronchus. In current clinical practice, these bronchi are sealed with sutures or staplers. This study investigated in an ex vivo pig model whether a new bipolar sealing device MARSEAL (KLS Martin, Tuttlingen, Germany) could be an alternative for this purpose. Complete bronchial trees were prepared free from pig heart-lung blocks that were removed at a slaughterhouse. These preparations were taken to the laboratory, and main, lobar, and segmental bronchi were closed using sutures, staples, or bipolar sealing. Each trachea was then intubated and connected to a ventilating device. The initial airtight closure of the bronchus was first tested with lung-protective ventilation. After 15 minutes of ventilation, the inspiratory ventilation pressure was slowly increased and the burst pressure (in mbar) was recorded. Each group included 12 bronchus closures. Group mean burst pressures were compared using a nonparametric test (Mann-Whitney test). The significance level was < 0.05. The main bronchi closed both stapler magazines or sutures were all initially airtight during ventilation. The mean burst pressure was 60 ± 0 mbar for staplers and 57.92 ± 5.8 mbar for sutures. In contrast, 50% of main bronchi sealed with MARSEAL devices (5 or 10 mm) leaked air from the beginning. This was also noted in all lobar bronchi sealed with the MARSEAL 5-mm device and 80% of those sealed with the MARSEAL 10-mm device. The mean burst pressure of initially airtight lobar bronchi was 12.7 ± 7.25 mbar. In contrast, all segmental bronchi (mean width: 1.6 cm) were airtight when ventilated. Mean burst pressure was 14.64 ± 9.1 mbar with the MARSEAL 5-mm device and 29.64 ± 21.3 mbar with the MARSEAL 10-mm device. Histological investigation of the preparations (with hematoxylin and eosin staining) showed intact cartilaginous structures that were largely unaffected by bipolar coagulation. The airtight sealing of the segmental bronchi resulted from fusion of the peribronchial tissue and not the cartilage. Bipolar sealing is an inappropriate tool for the closure of the bronchi in comparison to suture or stapling.
Every anatomical lung resection requires the airtight closure of at least one bronchus. In current clinical practice, these bronchi are sealed with sutures or staplers. This study investigated in an ex vivo pig model whether a new bipolar sealing device MARSEAL (KLS Martin, Tuttlingen, Germany) could be an alternative for this purpose. Complete bronchial trees were prepared free from pig heart-lung blocks that were removed at a slaughterhouse. These preparations were taken to the laboratory, and main, lobar, and segmental bronchi were closed using sutures, staples, or bipolar sealing. Each trachea was then intubated and connected to a ventilating device. The initial airtight closure of the bronchus was first tested with lung-protective ventilation. After 15 minutes of ventilation, the inspiratory ventilation pressure was slowly increased and the burst pressure (in mbar) was recorded. Each group included 12 bronchus closures. Group mean burst pressures were compared using a nonparametric test (Mann-Whitney test). The significance level was < 0.05. The main bronchi closed both stapler magazines or sutures were all initially airtight during ventilation. The mean burst pressure was 60 ± 0 mbar for staplers and 57.92 ± 5.8 mbar for sutures. In contrast, 50% of main bronchi sealed with MARSEAL devices (5 or 10 mm) leaked air from the beginning. This was also noted in all lobar bronchi sealed with the MARSEAL 5-mm device and 80% of those sealed with the MARSEAL 10-mm device. The mean burst pressure of initially airtight lobar bronchi was 12.7 ± 7.25 mbar. In contrast, all segmental bronchi (mean width: 1.6 cm) were airtight when ventilated. Mean burst pressure was 14.64 ± 9.1 mbar with the MARSEAL 5-mm device and 29.64 ± 21.3 mbar with the MARSEAL 10-mm device. Histological investigation of the preparations (with hematoxylin and eosin staining) showed intact cartilaginous structures that were largely unaffected by bipolar coagulation. The airtight sealing of the segmental bronchi resulted from fusion of the peribronchial tissue and not the cartilage. Bipolar sealing is an inappropriate tool for the closure of the bronchi in comparison to suture or stapling.
Prevention of bronchial complications after airway surgery must be our primary goal.Understanding bronchial and anastomotic healing is the first step to success. This can be improved by standardizing operating technique (bronchial closure and end-to-end anastomosis) as well as postoperative care. Bronchopleural fistula after pneumonectomy still remains a feared complication with a high mortality rate. Especially after sleeve resection interpretation of endobronchial healing and postoperative measures of care with the help of an algorithm, may avoid anastomotic insufficiency and therefore reduced the secondary pneumonectomy rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.